a1100

M9X046

Plenum

MECHANICAL, ENVIRONMENTAL & FLAME CHARACTERISTICS:

Crush Resistance                   EIA-455-41                        2,000 Newtons/cm
Impact Resistance                  EIA-455-25                        2,000 Impacts with 1.6 newton-meter
Flexure                                       EIA-455-104                      2,000 Cycles minimum
Minimum Bend Radius          Long-term – No Load       10 x Cable diameter
Minimum Bend Radius          Short-term – Load             15 x Cable diameter
Operating Temperature                                                      -20° C to 70° C
Storage Temperature                                                          -40° C to 80° C
UL Rated                                   Type OFNP
Flame Resistance                   UL 910 Modified                Passed

USES: Plenum wiring, office wiring, and computer room wiring.

PRODUCT FEATURES: 900 µm tight buffered fibers. Color coded for easy termination. Flame-retardant UL listed for code compliance.

Specifications

Minimum Bend Radius - Long Term
2.2 in
5.6 cm
Minimum Bend Radius - Short Term
3.3 in
8.4 cm
Fiber Count
8
For X in Part Number use…
Maximum Load (Installation)
180 lbs
801 N
Outside Diameter
0.222 in
5.64 mm
Weight
25 lbs/1000 ft
37 kgs/km