CONDUCTOR: Solid and stranded tinned copper.
INSULATION: PVC.
JACKET: PVC.
COLOR: Gray.*
VOLTAGE: 300 V / 150 V.
UL: CM / CL2 / CL3 (R).
CONSTRUCTION: Conductors cabled. Overall shield of 100% aluminum polyester foil with a stranded tinned copper drain wire.
USES: Used extensively for remote signaling circuits, broadcast systems, sound systems, intercom systems, audio systems, and instrumentation in compliance with the National Electric Code, NEC article 725 type CL3 or NEC article 800 type CM, as applicable.
* Custom jacket colors available.
Catalog No. | AWG Size | Insulation Thickness | Jacket Thickness | No. of Cond. | Nominal O.D. | Put Up | Stranding | Weight | Color Code |
---|---|---|---|---|---|---|---|---|---|
1326-13A | 22 |
0.008 in 0.203 mm |
0.020 in 0.508 mm |
6 |
0.190 in 4.83 mm |
1000 ft | 7/30 |
24 lbs/1000 ft 36 kgs/km |
Chart 1 |
1326-14A | 22 |
0.008 in 0.203 mm |
0.020 in 0.508 mm |
8 |
0.210 in 5.33 mm |
1000 ft | 7/30 |
29 lbs/1000 ft 43 kgs/km |
Chart 1 |
1326-16A | 22 |
0.008 in 0.203 mm |
0.020 in 0.508 mm |
10 |
0.230 in 5.84 mm |
1000 ft | 7/30 |
35 lbs/1000 ft 52 kgs/km |
Chart 1 |
1326-17A | 22 |
0.008 in 0.203 mm |
0.020 in 0.508 mm |
12 |
0.250 in 6.35 mm |
1000 ft | 7/30 |
41 lbs/1000 ft 61 kgs/km |
Chart 1 |
1327-6A | 18 |
0.010 in 0.254 mm |
0.025 in 0.635 mm |
6 |
0.285 in 7.24 mm |
1000 ft | 16/30 |
54 lbs/1000 ft 80 kgs/km |
Chart 1 |
504-14A | 22 |
0.008 in 0.203 mm |
0.020 in 0.508 mm |
2 |
0.130 in 3.30 mm |
1000 ft | Solid |
12 lbs/1000 ft 18 kgs/km |
Chart 1 |
504-15A | 22 |
0.008 in 0.203 mm |
0.020 in 0.508 mm |
2 |
0.130 in 3.30 mm |
1000 ft | 7/30 |
14 lbs/1000 ft 21 kgs/km |
Chart 1 |
504-20A | 22 |
0.008 in 0.203 mm |
0.020 in 0.508 mm |
3 |
0.150 in 3.81 mm |
1000 ft | 7/30 |
16 lbs/1000 ft 24 kgs/km |
Chart 1 |
504-24A | 22 |
0.008 in 0.203 mm |
0.020 in 0.508 mm |
4 |
0.165 in 4.19 mm |
1000 ft | 7/30 |
18 lbs/1000 ft 27 kgs/km |
Chart 1 |
504-34A | 20 |
0.010 in 0.254 mm |
0.020 in 0.508 mm |
2 |
0.150 in 3.81 mm |
1000 ft | 10/30 |
16 lbs/1000 ft 24 kgs/km |
Chart 1 |
504-49A | 20 |
0.010 in 0.254 mm |
0.020 in 0.508 mm |
3 |
0.160 in 4.06 mm |
1000 ft | 10/30 |
20 lbs/1000 ft 30 kgs/km |
Chart 1 |
504-67A | 18 |
0.010 in 0.254 mm |
0.025 in 0.635 mm |
2 |
0.175 in 4.45 mm |
1000 ft | 16/30 |
23 lbs/1000 ft 34 kgs/km |
Chart 1 |
504-71A | 18 |
0.010 in 0.254 mm |
0.025 in 0.635 mm |
3 |
0.190 in 4.83 mm |
1000 ft | 16/30 |
31 lbs/1000 ft 46 kgs/km |
Chart 1 |
504-72A | 18 |
0.010 in 0.254 mm |
0.025 in 0.635 mm |
4 |
0.200 in 5.08 mm |
1000 ft | 16/30 |
37 lbs/1000 ft 55 kgs/km |
Chart 1 |
504-74A | 16 |
0.012 in 0.305 mm |
0.025 in 0.635 mm |
2 |
0.210 in 5.33 mm |
1000 ft | 26/30 |
34 lbs/1000 ft 51 kgs/km |
Chart 1 |
504-84A | 16 |
0.012 in 0.305 mm |
0.025 in 0.635 mm |
4 |
0.265 in 6.73 mm |
1000 ft | 26/30 |
62 lbs/1000 ft 92 kgs/km |
Chart 1 |
504-8A | 24 |
0.008 in 0.203 mm |
0.020 in 0.508 mm |
2 |
0.125 in 3.18 mm |
1000 ft | 7/30 |
10 lbs/1000 ft 15 kgs/km |
Chart 1 |