a1043

CONDUCTOR: Silver plated copper*.
INSULATION: Extruded PTFE 0.008″ (0.20 mm).
IDENTIFICATION: Surface printed as required by UL or CSA.
TEMPERATURE: 150° C for UL and 200° C for CSA.
VOLTAGE: Not specified by UL, 150V for CSA.

USES: Applications where weight and space savings are required. Due to thin wall insulation these wires are restricted to low voltage applications.
*Available in nickel plated copper conductors, silver or nickel plated high strength copper alloy conductor.

Part Number AWG Size Conductor Diameter Insulation Diameter Max Resistance @ 20°C (@ 68°F) Stranding Weight
1097-10 32 0.009 in
0.229 mm
0.029 in
0.74 mm
166 Ohms/1000 ft
545 Ohms/km
7/40 0.78 lbs/1000 ft
1.17 kgs/km
1097-10A 32 0.010 in
0.254 mm
0.029 in
0.74 mm
153 Ohms/1000 ft
502 Ohms/km
19/44 0.80 lbs/1000 ft
1.19 kgs/km
1097-10C 32 0.008 in
0.203 mm
0.027 in
0.69 mm
162 Ohms/1000 ft
531 Ohms/km
Solid 0.69 lbs/1000 ft
1.03 kgs/km
1097-21 30 0.012 in
0.305 mm
0.032 in
0.81 mm
97.5 Ohms/1000 ft
320 Ohms/km
7/38 1.02 lbs/1000 ft
1.52 kgs/km
1097-21A 30 0.012 in
0.305 mm
0.032 in
0.81 mm
96.1 Ohms/1000 ft
315 Ohms/km
19/42 1.03 lbs/1000 ft
1.53 kgs/km
1097-21C 30 0.010 in
0.254 mm
0.029 in
0.74 mm
104 Ohms/1000 ft
341 Ohms/km
Solid 0.86 lbs/1000 ft
1.28 kgs/km
1097-32 28 0.015 in
0.381 mm
0.035 in
0.89 mm
62.0 Ohms/1000 ft
203 Ohms/km
7/36 1.32 lbs/1000 ft
1.96 kgs/km
1097-32A 28 0.015 in
0.381 mm
0.035 in
0.89 mm
63.1 Ohms/1000 ft
207 Ohms/km
19/40 1.32 lbs/1000 ft
1.96 kgs/km
1097-32C 28 0.013 in
0.330 mm
0.032 in
0.81 mm
65.3 Ohms/1000 ft
214 Ohms/km
Solid 1.13 lbs/1000 ft
1.68 kgs/km
1097-43 26 0.019 in
0.483 mm
0.038 in
0.97 mm
38.7 Ohms/1000 ft
127 Ohms/km
7/34 1.71 lbs/1000 ft
2.54 kgs/km
1097-43A 26 0.019 in
0.483 mm
0.038 in
0.97 mm
37.3 Ohms/1000 ft
122 Ohms/km
19/38 1.74 lbs/1000 ft
2.59 kgs/km
1097-43C 26 0.016 in
0.406 mm
0.035 in
0.89 mm
41.0 Ohms/1000 ft
135 Ohms/km
Solid 1.49 lbs/1000 ft
2.22 kgs/km
1097-5 36 0.006 in
0.152 mm
0.025 in
0.64 mm
412 Ohms/1000 ft
1352 Ohms/km
7/44 0.52 lbs/1000 ft
0.77 kgs/km
1097-54 24 0.024 in
0.610 mm
0.043 in
1.09 mm
23.9 Ohms/1000 ft
78.4 Ohms/km
7/32 2.41 lbs/1000 ft
3.59 kgs/km
1097-54A 24 0.024 in
0.610 mm
0.043 in
1.09 mm
23.6 Ohms/1000 ft
77.4 Ohms/km
19/36 2.41 lbs/1000 ft
3.59 kgs/km
1097-54C 24 0.020 in
0.508 mm
0.040 in
1.02 mm
25.7 Ohms/1000 ft
84.3 Ohms/km
Solid 2.12 lbs/1000 ft
3.15 kgs/km
1097-65 22 0.030 in
0.76 mm
0.050 in
1.27 mm
15.2 Ohms/1000 ft
49.9 Ohms/km
7/30 3.47 lbs/1000 ft
5.16 kgs/km
1097-65A 22 0.030 in
0.76 mm
0.050 in
1.27 mm
14.8 Ohms/1000 ft
48.6 Ohms/km
19/34 3.51 lbs/1000 ft
5.22 kgs/km
1097-65C 22 0.025 in
0.64 mm
0.046 in
1.17 mm
16.5 Ohms/1000 ft
54.1 Ohms/km
Solid 3.06 lbs/1000 ft
4.55 kgs/km
1097-76 20 0.038 in
0.97 mm
0.058 in
1.47 mm
9.56 Ohms/1000 ft
31.4 Ohms/km
7/28 5.05 lbs/1000 ft
7.51 kgs/km
1097-76A 20 0.038 in
0.97 mm
0.058 in
1.47 mm
8.87 Ohms/1000 ft
29.1 Ohms/km
19/32 5.15 lbs/1000 ft
7.66 kgs/km
1097-76C 20 0.032 in
0.81 mm
0.054 in
1.37 mm
10.1 Ohms/1000 ft
33.1 Ohms/km
Solid 4.89 lbs/1000 ft
7.28 kgs/km
1097-8 34 0.008 in
0.203 mm
0.028 in
0.71 mm
258 Ohms/1000 ft
846 Ohms/km
7/42 0.67 lbs/1000 ft
1.00 kgs/km
1097-87 18 0.048 in
1.22 mm
0.068 in
1.73 mm
6.01 Ohms/1000 ft
19.7 Ohms/km
7/26 7.50 lbs/1000 ft
11.2 kgs/km
1097-87A 18 0.047 in
1.19 mm
0.068 in
1.73 mm
5.79 Ohms/1000 ft
19.0 Ohms/km
19/30 7.50 lbs/1000 ft
11.2 kgs/km
1097-98A 16 0.053 in
1.35 mm
0.077 in
1.96 mm
4.52 Ohms/1000 ft
14.8 Ohms/km
19/29 9.65 lbs/1000 ft
14.4 kgs/km