2.0 mm subunit – Plenum
MECHANICAL, ENVIRONMENTAL & FLAME CHARACTERISTICS:
Crush Resistance EIA-455-41 2,000 Newtons/cm
Impact Resistance EIA-455-25 2,000 Impacts with 1.6 newton-meter
Flexure EIA-455-104 2,000 Cycles minimum
Minimum Bend Radius Long-term – No Load 10 x Cable diameter
Minimum Bend Radius Short-term – Load 15 x Cable diameter
Operating Temperature -20° C to 70° C
Storage Temperature -40° C to 80° C
UL Rated Type OFNP
Flame Resistance UL 910 Modified Passed
USES: Plenum wiring, office wiring, and computer room wiring.
PRODUCT FEATURES: 900 µm tight buffered fibers. Color coded for easy termination. Flame-retardant. UL listed for code compliance. 2-12 fibers per DEC specifications.
For “X” in part number, see optical characteristics chart
Part Number | Minimum Bend Radius - Long Term | Minimum Bend Radius - Short Term | Fiber Count | Maximum Load (Installation) | Outside Diameter | Weight | For X in Part Number use… |
---|---|---|---|---|---|---|---|
M9X013 |
1.9 in 4.8 cm |
2.9 in 7 cm |
2 |
224 lbs 996 N |
0.191 in 4.85 mm |
20 lbs/1000 ft 30 kgs/km |
Chart |
M9X014 |
2.2 in 5.6 cm |
3.4 in 9 cm |
4 |
600 lbs 2,669 N |
0.224 in 5.69 mm |
25 lbs/1000 ft 37 kgs/km |
Chart |
M9X015 |
2.8 in 7.1 cm |
4.2 in 11 cm |
6 |
600 lbs 2,669 N |
0.280 in 7.11 mm |
40 lbs/1000 ft 60 kgs/km |
Chart |
M9X016 |
3.4 in 8.6 cm |
5.1 in 13 cm |
8 |
600 lbs 2,669 N |
0.342 in 8.69 mm |
60 lbs/1000 ft 89 kgs/km |
Chart |
M9X017 |
3.9 in 9.9 cm |
5.8 in 15 cm |
10 |
600 lbs 2,669 N |
0.387 in 9.83 mm |
80 lbs/1000 ft 119 kgs/km |
Chart |
M9X018 |
4.6 in 12 cm |
6.9 in 18 cm |
12 |
600 lbs 2,669 N |
0.458 in 11.6 mm |
100 lbs/1000 ft 149 kgs/km |
Chart |
M9X019 |
4.6 in 12 cm |
6.9 in 18 cm |
18 |
600 lbs 2,669 N |
0.458 in 11.6 mm |
100 lbs/1000 ft 149 kgs/km |
Chart |
M9X020 |
5.6 in 14 cm |
8.4 in 21 cm |
24 |
600 lbs 2,669 N |
0.558 in 14.2 mm |
145 lbs/1000 ft 216 kgs/km |
Chart |
M9X082 |
6.0 in 15 cm |
9.0 in 23 cm |
36 |
600 lbs 2,669 N |
0.603 in 15.3 mm |
165 lbs/1000 ft 246 kgs/km |
Chart |