CONDUCTOR: Stranded silver-plated or nickel-plated copper. JACKET: Extruded FEP or wrapped PTFE with 0.008″ / 0.012″ wall thickness. Saturated glass fiber braid jackets are also available. CONSTRUCTION: Dielectric is PTFE with 0.008″ /0.012″ wall thickness. Cable twisting 1.5 to 2.5 inch lay. Shield is silver-plated or nickel-plated copper, 90% minimum coverage.
SPECIFICATION: The individually insulated conductors are manufactured to meet the requirements of MIL-W-16878/4 Type E. These cables can also be manufactured to MIL-C-55021 & MIL-DTL-27500 upon request. Also available with MIL-W-16878/5 Type EE and MIL-W-16878/6 Type ET conductors.
COLOR: Primary conductors are color coded per the requirements of MIL-C-915. Custom color coding per your requirement is available upon request. All colors remain fast on continuous exposure to light, heat, or solvents, and conform to MIL-STD-104. Primary insulation (dielectric) with wrapped PTFE jackets or extruded FEP jackets are available in the following colors: Black, brown, red, orange, yellow, green, blue, purple, gray, and white.
USES: When temperature requirements range from -65° C to 260° C at 600 volt RMS maximum (silver-plated: -65° C to 200° C; nickel-plated: -65° C to 260° C.)
The Letter in Catalog No. Indicates:
E = Wrapped PTFE jacket.
F = Extruded FEP jacket.
All dimensions are nominal.
Catalog No. | AWG Size | Conductor O.D. | Insulation O.D. | Jacket O.D. | Shield O.D. | Stranding | Weight |
---|---|---|---|---|---|---|---|
1100-22E | 30 |
0.012 in 0.30 mm |
0.032 in 0.81 mm |
0.107 in 2.72 mm |
0.086 in 2.18 mm |
7/38 |
8.73 lbs/1000 ft 13.0 kgs/km |
1100-22F | 30 |
0.012 in 0.30 mm |
0.032 in 0.81 mm |
0.107 in 2.72 mm |
0.086 in 2.18 mm |
7/38 |
8.73 lbs/1000 ft 13.0 kgs/km |
1100-33E | 28 |
0.015 in 0.38 mm |
0.035 in 0.89 mm |
0.113 in 2.87 mm |
0.092 in 2.34 mm |
7/36 |
9.56 lbs/1000 ft 14.2 kgs/km |
1100-33F | 28 |
0.015 in 0.38 mm |
0.035 in 0.89 mm |
0.113 in 2.87 mm |
0.092 in 2.34 mm |
7/36 |
9.56 lbs/1000 ft 14.2 kgs/km |
1100-44E | 26 |
0.019 in 0.48 mm |
0.039 in 0.99 mm |
0.122 in 3.10 mm |
0.100 in 2.54 mm |
19/38 |
11.7 lbs/1000 ft 17.4 kgs/km |
1100-44F | 26 |
0.019 in 0.48 mm |
0.039 in 0.99 mm |
0.122 in 3.10 mm |
0.100 in 2.54 mm |
19/38 |
11.7 lbs/1000 ft 17.4 kgs/km |
1100-55E | 24 |
0.025 in 0.64 mm |
0.045 in 1.14 mm |
0.135 in 3.43 mm |
0.112 in 2.84 mm |
19/36 |
13.8 lbs/1000 ft 20.5 kgs/km |
1100-55F | 24 |
0.025 in 0.64 mm |
0.045 in 1.14 mm |
0.135 in 3.43 mm |
0.112 in 2.84 mm |
19/36 |
13.8 lbs/1000 ft 20.5 kgs/km |
1100-66E | 22 |
0.031 in 0.79 mm |
0.051 in 1.30 mm |
0.148 in 3.76 mm |
0.124 in 3.15 mm |
19/34 |
16.5 lbs/1000 ft 24.6 kgs/km |
1100-66F | 22 |
0.031 in 0.79 mm |
0.051 in 1.30 mm |
0.148 in 3.76 mm |
0.124 in 3.15 mm |
19/34 |
16.5 lbs/1000 ft 24.6 kgs/km |
1100-77E | 20 |
0.040 in 1.02 mm |
0.060 in 1.52 mm |
0.167 in 4.24 mm |
0.142 in 3.61 mm |
19/32 |
21.3 lbs/1000 ft 31.7 kgs/km |
1100-77F | 20 |
0.040 in 1.02 mm |
0.060 in 1.52 mm |
0.167 in 4.24 mm |
0.142 in 3.61 mm |
19/32 |
21.3 lbs/1000 ft 31.7 kgs/km |
1100-88E | 18 |
0.050 in 1.27 mm |
0.070 in 1.78 mm |
0.189 in 4.80 mm |
0.162 in 4.11 mm |
19/30 |
27.8 lbs/1000 ft 41.4 kgs/km |
1100-88F | 18 |
0.050 in 1.27 mm |
0.070 in 1.78 mm |
0.189 in 4.80 mm |
0.162 in 4.11 mm |
19/30 |
27.8 lbs/1000 ft 41.4 kgs/km |
1100-99E | 16 |
0.057 in 1.45 mm |
0.080 in 2.03 mm |
0.208 in 5.28 mm |
0.188 in 4.78 mm |
19/29 |
33.4 lbs/1000 ft 49.7 kgs/km |
1100-99F | 16 |
0.057 in 1.45 mm |
0.080 in 2.03 mm |
0.208 in 5.28 mm |
0.188 in 4.78 mm |
19/29 |
33.4 lbs/1000 ft 49.7 kgs/km |