CONDUCTOR: Stranded tinned copper.
INSULATION: 105° C, PVC/nylon, white, black, red*. Conforms to MIL-DTL-16878.
SHIELD: Tinned copper braid.
JACKET: PVC, white*.
VOLTAGE: 600 V, 1000 V, 3000 V.
* Primary conductors are color coded per the requirements of MIL-C-7078 or MIL-C-915. Custom color coding is available upon request.
Catalog No. | AWG Size | Nominal Diameter | Stranding | Type | Weight |
---|---|---|---|---|---|
500-14 | 26 |
0.139 in 3.53 mm |
7/34 | B/Nylon 600 V |
16.1 lbs/1000 ft 24.0 kgs/km |
500-25 | 24 |
0.151 in 3.84 mm |
7/32 | B/Nylon 600 V |
19.7 lbs/1000 ft 29.3 kgs/km |
500-25A | 24 |
0.151 in 3.84 mm |
19/36 | B/Nylon 600 V |
20.1 lbs/1000 ft 29.8 kgs/km |
500-36A | 22 |
0.168 in 4.27 mm |
19/34 | B/Nylon 600 V |
27.4 lbs/1000 ft 40.7 kgs/km |
500-47A | 20 |
0.187 in 4.75 mm |
19/32 | B/Nylon 600 V |
31.8 lbs/1000 ft 47.4 kgs/km |
500-58A | 18 |
0.217 in 5.51 mm |
19/30 | B/Nylon 600 V |
43.6 lbs/1000 ft 64.8 kgs/km |
500-69A | 16 |
0.243 in 6.17 mm |
19/29 | B/Nylon 600 V |
53.1 lbs/1000 ft 79.0 kgs/km |
500-80A | 14 |
0.283 in 7.19 mm |
19/27 | B/Nylon 600 V |
71.0 lbs/1000 ft 106 kgs/km |
501-25 | 24 |
0.092 in 2.34 mm |
7/32 | C/Nylon 1000 V |
26.8 lbs/1000 ft 39.8 kgs/km |
501-25A | 24 |
0.206 in 5.23 mm |
19/36 | C/Nylon 1000 V |
27.2 lbs/1000 ft 40.4 kgs/km |
501-36A | 22 |
0.230 in 5.84 mm |
19/34 | C/Nylon 1000 V |
31.8 lbs/1000 ft 47.3 kgs/km |
501-47A | 20 |
0.257 in 6.53 mm |
19/32 | C/Nylon 1000 V |
47.4 lbs/1000 ft 70.5 kgs/km |
501-58A | 18 |
0.285 in 7.24 mm |
19/30 | C/Nylon 1000 V |
63.8 lbs/1000 ft 94.9 kgs/km |
501-69A | 16 |
0.321 in 8.15 mm |
19/29 | C/Nylon 1000 V |
73.3 lbs/1000 ft 109 kgs/km |
501-80A | 14 |
0.376 in 9.55 mm |
19/27 | C/Nylon 1000 V |
101 lbs/1000 ft 150 kgs/km |
501-91A | 12 |
0.390 in 9.91 mm |
19/25 | C/Nylon 1000 V |
123 lbs/1000 ft 183 kgs/km |
502-102A | 10 |
0.564 in 14.3 mm |
37/26 | D/Nylon 3000 V |
216 lbs/1000 ft 321 kgs/km |
502-113A | 8 |
0.705 in 17.9 mm |
133/29 | D/Nylon 3000 V |
356 lbs/1000 ft 529 kgs/km |
502-36A | 22 |
0.278 in 7.06 mm |
19/34 | D/Nylon 3000 V |
51.3 lbs/1000 ft 76.4 kgs/km |
502-47A | 20 |
0.298 in 7.57 mm |
19/32 | D/Nylon 3000 V |
58.2 lbs/1000 ft 86.6 kgs/km |
502-58A | 18 |
0.323 in 8.20 mm |
19/30 | D/Nylon 3000 V |
67.1 lbs/1000 ft 99.9 kgs/km |
502-69A | 16 |
0.349 in 8.86 mm |
19/29 | D/Nylon 3000 V |
78.4 lbs/1000 ft 117 kgs/km |
502-80A | 14 |
0.389 in 9.88 mm |
19/27 | D/Nylon 3000 V |
103 lbs/1000 ft 153 kgs/km |
502-91A | 12 |
0.483 in 12.3 mm |
19/25 | D/Nylon 3000 V |
152 lbs/1000 ft 226 kgs/km |