CONDUCTOR: Stranded tinned copper.
INSULATION: 105° C, PVC/nylon, white, black*. Conforms to MIL-DTL-16878.
SHIELD: Tinned copper braid.
JACKET: PVC, white*.
VOLTAGE: 600 V, 1000 V, 3000 V.
* Primary conductors are color coded per the requirements of MIL-C-7078 or MIL-C-915. Custom color coding is available upon request.
Catalog No. | AWG Size | Nominal Diameter | Stranding | Type | Weight |
---|---|---|---|---|---|
500-12 | 26 |
0.132 in 3.35 mm |
7/34 | B/Nylon 600 V |
14.0 lbs/1000 ft 20.8 kgs/km |
500-23 | 24 |
0.142 in 3.61 mm |
7/32 | B/Nylon 600 V |
16.5 lbs/1000 ft 24.6 kgs/km |
500-23A | 24 |
0.142 in 3.61 mm |
19/36 | B/Nylon 600 V |
16.8 lbs/1000 ft 24.9 kgs/km |
500-34A | 22 |
0.158 in 4.01 mm |
19/34 | B/Nylon 600 V |
20.4 lbs/1000 ft 30.4 kgs/km |
500-45A | 20 |
0.176 in 4.47 mm |
19/32 | B/Nylon 600 V |
26.1 lbs/1000 ft 38.9 kgs/km |
500-56A | 18 |
0.202 in 5.13 mm |
19/30 | B/Nylon 600 V |
34.4 lbs/1000 ft 51.1 kgs/km |
500-67A | 16 |
0.228 in 5.79 mm |
19/29 | B/Nylon 600 V |
41.7 lbs/1000 ft 62.0 kgs/km |
500-78A | 14 |
0.264 in 6.71 mm |
19/27 | B/Nylon 600 V |
55.9 lbs/1000 ft 83.1 kgs/km |
501-23 | 24 |
0.180 in 4.57 mm |
7/32 | C/Nylon 1000 V |
22.1 lbs/1000 ft 32.9 kgs/km |
501-23A | 24 |
0.180 in 4.57 mm |
19/36 | C/Nylon 1000 V |
22.3 lbs/1000 ft 33.2 kgs/km |
501-34A | 22 |
0.194 in 4.93 mm |
19/34 | C/Nylon 1000 V |
26.0 lbs/1000 ft 38.7 kgs/km |
501-45A | 20 |
0.216 in 5.49 mm |
19/32 | C/Nylon 1000 V |
33.0 lbs/1000 ft 49.1 kgs/km |
501-56A | 18 |
0.242 in 6.15 mm |
19/30 | C/Nylon 1000 V |
44.3 lbs/1000 ft 65.9 kgs/km |
501-67A | 16 |
0.266 in 6.76 mm |
19/29 | C/Nylon 1000 V |
49.2 lbs/1000 ft 73.3 kgs/km |
501-78A | 14 |
0.302 in 7.67 mm |
19/27 | C/Nylon 1000 V |
65.8 lbs/1000 ft 97.9 kgs/km |
501-89A | 12 |
0.352 in 8.94 mm |
19/25 | C/Nylon 1000 V |
88.9 lbs/1000 ft 132 kgs/km |
502-100A | 10 |
0.504 in 12.8 mm |
37/26 | D/Nylon 3000 V |
157 lbs/1000 ft 233 kgs/km |
502-111A | 8 |
0.630 in 16.0 mm |
133/29 | D/Nylon 3000 V |
249 lbs/1000 ft 371 kgs/km |
502-34A | 22 |
0.258 in 6.55 mm |
19/34 | D/Nylon 3000 V |
40.8 lbs/1000 ft 60.7 kgs/km |
502-45A | 20 |
0.280 in 7.11 mm |
19/32 | D/Nylon 3000 V |
47.5 lbs/1000 ft 70.7 kgs/km |
502-56A | 18 |
0.302 in 7.67 mm |
19/30 | D/Nylon 3000 V |
55.3 lbs/1000 ft 82.3 kgs/km |
502-67A | 16 |
0.324 in 8.23 mm |
19/29 | D/Nylon 3000 V |
62.2 lbs/1000 ft 92.5 kgs/km |
502-78A | 14 |
0.364 in 9.25 mm |
19/27 | D/Nylon 3000 V |
80.7 lbs/1000 ft 120 kgs/km |
502-89A | 12 |
0.446 in 11.3 mm |
19/25 | D/Nylon 3000 V |
117 lbs/1000 ft 174 kgs/km |