a1077

CONDUCTOR: Stranded nickel-plated copper.
TEMPERATURE: -55° C to 260° C.
VOLTAGE: 600 V.
INSULATION: PTFE, reinforced with abrasion resistant mineral fillers.

USES: Wire for high temperature use having good flexibility. For use where abrasion resistance is required.

NOTE: MIL-DTL-27500 Basic Wire Specification : WA

Catalog No. AWG Size Max. Diameter Min. Diameter Max Resistance @ 20°C (@ 68°F) Stranding Weight
1166-32 24 0.080 in
2.03 mm
0.070 in
1.78 mm
25.9 Ohms/1000 ft
85.0 Ohms/km
19/36 6.00 lbs/1000 ft
8.93 kgs/km
1166-34 22 0.090 in
2.29 mm
0.080 in
2.03 mm
16.0 Ohms/1000 ft
52.5 Ohms/km
19/34 8.00 lbs/1000 ft
11.9 kgs/km
1166-39 20 0.100 in
2.54 mm
0.090 in
2.29 mm
9.77 Ohms/1000 ft
32.1 Ohms/km
19/32 10.0 lbs/1000 ft
14.9 kgs/km
1166-44 18 0.115 in
2.92 mm
0.105 in
2.67 mm
6.10 Ohms/1000 ft
20.0 Ohms/km
19/30 14.0 lbs/1000 ft
20.8 kgs/km
1166-49 16 0.130 in
3.30 mm
0.120 in
3.05 mm
4.76 Ohms/1000 ft
15.6 Ohms/km
19/29 18.0 lbs/1000 ft
26.8 kgs/km
1166-54 14 0.150 in
3.81 mm
0.136 in
3.45 mm
3.00 Ohms/1000 ft
9.84 Ohms/km
19/27 25.0 lbs/1000 ft
37.2 kgs/km
1166-60 12 0.167 in
4.24 mm
0.153 in
3.89 mm
1.89 Ohms/1000 ft
6.20 Ohms/km
19/25 34.5 lbs/1000 ft
51.3 kgs/km
1166-64 10 0.186 in
4.72 mm
0.172 in
4.37 mm
1.24 Ohms/1000 ft
4.07 Ohms/km
37/26 48.0 lbs/1000 ft
71.4 kgs/km
1166-69 8 0.255 in
6.48 mm
0.241 in
6.12 mm
0.694 Ohms/1000 ft
2.28 Ohms/km
133/29 83.7 lbs/1000 ft
125 kgs/km
1166-74 6 0.310 in
7.87 mm
0.290 in
7.37 mm
0.436 Ohms/1000 ft
1.43 Ohms/km
133/27 127 lbs/1000 ft
189 kgs/km
1166-79 4 0.370 in
9.40 mm
0.340 in
8.64 mm
0.275 Ohms/1000 ft
0.902 Ohms/km
133/25 190 lbs/1000 ft
283 kgs/km