* Covered by specification MIL-DTL-17
Catalog No. | RG/U No. | Cap. | Dielectric Material | Nom. Imp. | Jacket | Overall Diameter | Shield | Size (in) and Type of Inner Cond. | Type |
---|---|---|---|---|---|---|---|---|---|
258 | 258 |
24.4 pF/ft 80.1 pF/m |
PE tube | 50 Ω |
PE PE |
1.936 max. in 49.17 max. mm |
Al tube | BC tube | Coax Cable |
507-10 | 10 |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-II w/armor PVC-II w/armor |
0.475 in 12.1 mm |
BC | 7/21 BC | Coax Cable |
507-100 | 100 |
44.0 pF/ft 144 pF/m |
PE | 35 Ω |
PVC-I PVC-I |
0.242 in 6.15 mm |
BC | 19/0.0147 BC | Coax Cable |
507-101 | 101 |
N/A N/A |
Rubber | 75 Ω |
- - |
0.588 in 14.9 mm |
TC | 0.0641 BC | Coax Cable |
507-102 | 102 |
N/A N/A |
Rubber | 140 Ω |
- - |
1.088 in 27.64 mm |
TC | 2 cond. 0.0808 BC | Coax Cable |
507-103 | 103 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-104 | 104 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-105 | 105 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-106 | 106 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-107 | 107 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-108 | 108 |
24.5 pF/ft 80.4 pF/m |
PE | 78 Ω |
XL polyolefin XL polyolefin |
0.235 in 5.97 mm |
TC | 2 cond. 7/28 TC | Coax Cable |
507-108A | 108A* |
24.5 pF/ft 80.4 pF/m |
PE | 78 Ω |
XL polyolefin XL polyolefin |
0.235 in 5.97 mm |
TC | 2 cond. 7/28 TC | Coax Cable |
507-109 | 109 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-10A | 10A* |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-IIA w/armor PVC-IIA w/armor |
0.475 in 12.1 mm |
BC | 7/21 BC | Coax Cable |
507-11 | 11 |
22.0 pF/ft 72.2 pF/m |
PE | 75 Ω |
PVC-I PVC-I |
0.405 in 10.3 mm |
BC | 7/26 TC | Coax Cable |
507-110 | 110 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-111 | 111 |
18.4 pF/ft 60.4 pF/m |
PE | 95 Ω |
PVC-II w/armor PVC-II w/armor |
0.490 in 12.4 mm |
2 TC | 2 cond. 7/0.0152 BC | Coax Cable |
507-111A | 111A* |
18.4 pF/ft 60.4 pF/m |
PE | 95 Ω |
PVC-IIA w/armor PVC-IIA w/armor |
0.490 in 12.4 mm |
2 TC | 2 cond. 7/0.0152 BC | Coax Cable |
507-112 | 112 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-113 | 113 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-114 | 114 |
6.8 pF/ft 22 pF/m |
Air space PE | 185 Ω |
PVC-IIA PVC-IIA |
0.405 in 10.3 mm |
BC | 0.0070 CW | Coax Cable |
507-114A | 114A* |
6.8 pF/ft 22 pF/m |
Air space PE | 185 Ω |
PVC-IIA PVC-IIA |
0.405 in 10.3 mm |
BC | 0.0070 CW | Coax Cable |
507-115 | 115* |
32.0 pF/ft 105 pF/m |
TFE tape | 50 Ω |
FG-V FG-V |
0.415 in 10.5 mm |
2 S | 7/21 S | Coax Cable |
507-115A | 115A* |
32.0 pF/ft 105 pF/m |
TFE tape | 50 Ω |
FG-V FG-V |
0.415 in 10.5 mm |
2 S | 7/21 S | Coax Cable |
507-116 | 116* |
29.5 pF/ft 96.8 pF/m |
TFE | 50 Ω |
FG-V w/armor FG-V w/armor |
0.475 in 12.1 mm |
2 S | 7/20 S | Coax Cable |
507-117 | 117* |
29.5 pF/ft 96.8 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.730 in 18.5 mm |
BC | 0.188 BC | Coax Cable |
507-117A | 117A* |
29.5 pF/ft 96.8 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.730 in 18.5 mm |
BC | 0.188 BC | Coax Cable |
507-118 | 118* |
29.0 pF/ft 95.1 pF/m |
TFE | 50 Ω |
FG-V w/armor FG-V w/armor |
0.780 in 19.8 mm |
BC | 0.188 BC | Coax Cable |
507-118A | 118A* |
50 Ω 95.1 pF/m |
TFE | 50 Ω |
FG-V w/armor FG-V w/armor |
0.780 in 19.8 mm |
BC | 0.188 BC | Coax Cable |
507-119 | 119* |
29.3 pF/ft 96.1 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.465 in 11.8 mm |
2 BC | 0.102 BC | Coax Cable |
507-11A | 11A* |
22.0 pF/ft 72.2 pF/m |
PE | 75 Ω |
PVC-IIA PVC-IIA |
0.405 in 10.3 mm |
BC | 7/26 TC | Coax Cable |
507-12 | 12 |
20.5 pF/ft 67.3 pF/m |
PE | 75 Ω |
PVC-II w/armor PVC-II w/armor |
0.475 in 12.1 mm |
BC | 7/26 TC | Coax Cable |
507-120 | 120* |
29.3 pF/ft 96.1 pF/m |
TFE | 50 Ω |
FG-V w/armor FG-V w/armor |
0.523 in 13.3 mm |
2 BC | 0.102 BC | Coax Cable |
507-121 | 121 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-122 | 122* |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.160 in 4.06 mm |
TC | 27/36 TC | Coax Cable |
507-123 | 123 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Not assigned |
507-124 | 124 |
20.3 pF/ft 66.6 pF/m |
TFE tape | 73 Ω |
FG-V FG-V |
0.240 in 6.10 mm |
TC | 0.0253 TCW | Coax Cable |
507-125 | 125 |
7.8 pF/ft 26 pF/m |
Air space PE | 150 Ω |
PVC-IIA PVC-IIA |
0.600 in 15.2 mm |
BC | 0.0159 CW | Coax Cable |
507-126 | 126* |
29.0 pF/ft 95.1 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.280 in 7.11 mm |
HR | 7/24 HR | Coax Cable |
507-128 | 128 |
N/A N/A |
SS TFE | 50 Ω |
None None |
1.625 in 41.28 mm |
BC Tube | 0.644 BC | Coax Cable |
507-129 | 129 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Flexible Waveguide |
507-12A | 12A* |
20.5 pF/ft 67.3 pF/m |
PE | 75 Ω |
PVC-IIA w/armor PVC-IIA w/armor |
0.475 in 12.1 mm |
BC | 7/26 TC | Coax Cable |
507-13 | 13 |
20.5 pF/ft 67.3 pF/m |
PE | 74 Ω |
PVC-I PVC-I |
0.420 in 10.7 mm |
2 BC | 7/26 TC | Coax Cable |
507-130 | 130* |
17.0 pF/ft 55.8 pF/m |
PE | 95 Ω |
PVC-I PVC-I |
0.625 in 15.9 mm |
TC | 2 cond. 7/21 BC | Coax Cable |
507-131 | 131* |
17.0 pF/ft 55.8 pF/m |
PE | 95 Ω |
PVC-I w/armor PVC-I w/armor |
0.710 in 18.0 mm |
TC | 2 cond. 7/21 BC | Coax Cable |
507-132 | 132 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-133 | 133 |
16.2 pF/ft 53.1 pF/m |
PE | 95 Ω |
PVC-I PVC-I |
0.405 in 10.3 mm |
BC | 0.0285 BC | Coax Cable |
507-133A | 133A* |
16.2 pF/ft 53.1 pF/m |
PE | 95 Ω |
PVC-IIA PVC-IIA |
0.405 in 10.3 mm |
BC | 0.0253 BC | Coax Cable |
507-134 | 134 |
6.5 pF/ft 21 pF/m |
SS TFE | 185 Ω |
None None |
0.450 in 11.4 mm |
Brass | 0.0126 BC | Coax Cable |
507-135 | 135 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-136 | 136 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-137 | 137 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-138 | 138 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-139 | 139 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-13A | 13A* |
20.5 pF/ft 67.3 pF/m |
PE | 74 Ω |
PVC-IIA PVC-IIA |
0.420 in 10.7 mm |
2 BC | 7/26 TC | Coax Cable |
507-14 | 14 |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-II PVC-II |
0.545 in 13.8 mm |
2 BC | 0.1020 BC | Coax Cable |
507-140 | 140* |
21.0 pF/ft 68.9 pF/m |
TFE | 75 Ω |
FG-V FG-V |
0.233 in 5.92 mm |
S | 5.92 mm | Coax Cable |
507-141 | 141 |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.190 in 4.83 mm |
S | 0.0359 SCCS | Coax Cable |
507-141A | 141A* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.190 in 4.83 mm |
S | 0.0390 SCCS | Coax Cable |
507-142 | 142 |
29.3 pF/ft 96.1 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.195 in 4.95 mm |
2 S | 0.0370 SCCS | Coax Cable |
507-142A | 142A* |
29.3 pF/ft 96.1 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.195 in 4.95 mm |
2 S | 0.0370 SCCS | Coax Cable |
507-142B | 142B* |
29.3 pF/ft 96.1 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.195 in 4.95 mm |
2 S | 0.0370 SCCS | Coax Cable |
507-143 | 143 |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.325 in 8.26 mm |
2 S | 0.0570 SCCS | Coax Cable |
507-143A | 143A* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.325 in 8.26 mm |
2 S | 0.0590 SCCS | Coax Cable |
507-144 | 144* |
22.0 pF/ft 72.2 pF/m |
TFE | 75 Ω |
FG-V FG-V |
0.410 in 10.4 mm |
S | 7/25 SCCS | Coax Cable |
507-145 | 145 |
14.6 pF/ft 47.9 pF/m |
Air space PE | 75 Ω |
Lead-tar Lead-tar |
N/A N/A |
BC Tube | 2 cond. 0.0720 BC | Coax Cable |
507-146 | 146 |
6.0 pF/ft 20 pF/m |
Air space TFE | 190 Ω |
FG-V FG-V |
0.375 in 9.53 mm |
BC | 0.0070 CW | Coax Cable |
507-147 | 147 |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-I w/armor PVC-I w/armor |
1.938 in 49.23 mm |
BC | 0.250 BC | Coax Cable |
507-148 | 148 |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-I w/armor PVC-I w/armor |
0.800 in 20.3 mm |
BC | 7/21 BC | Coax Cable |
507-149 | 149* |
20.5 pF/ft 67.3 pF/m |
PE | 75 Ω |
PVC-IIA PVC-IIA |
0.405 in 10.3 mm |
BC | 7/26 TC | Coax Cable |
507-14A | 14A* |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-IIA PVC-IIA |
0.545 in 13.8 mm |
2 BC | 0.1020 BC | Coax Cable |
507-15 | 15 |
20.0 pF/ft 65.6 pF/m |
PE | 76 Ω |
PVC-I PVC-I |
0.545 in 13.8 mm |
2 BC | 0.0571 CW | Coax Cable |
507-150 | 150* |
20.5 pF/ft 67.3 pF/m |
PE | 75 Ω |
PVC-IIA w/armor PVC-IIA w/armor |
0.475 in 12.1 mm |
BC | 7/26 TC | Coax Cable |
507-151 | 151* |
N/A N/A |
N/A | 50 Ω |
None None |
0.375 in 9.53 mm |
BC Tube | 0.125 BC tube | Coax Cable |
507-152 | 152* |
N/A N/A |
N/A | 50 Ω |
None None |
6.125 in 156 mm |
BC Tube | 2.60 BC tube | Coax Cable |
507-153 | 153* |
N/A N/A |
N/A | 50 Ω |
None None |
1.625 in 41.28 mm |
BC Tube | 0.664 BC tube | Coax Cable |
507-154 | 154 |
N/A N/A |
N/A | 50 Ω |
None None |
3.125 in 79.38 mm |
BC Tube | 1.315 BC tube | Coax Cable |
507-155 | 155 |
N/A N/A |
N/A | 50 Ω |
N/A N/A |
0.875 in 22.2 mm |
BC Tube | 0.341 BC tube | Coax Cable |
507-156 | 156* |
32.8 pF/ft 108 pF/m |
PE & conductive PE | 50 Ω |
PVC-IIA PVC-IIA |
0.540 in 13.7 mm |
TC, GS, TC | 7/21 TC | Coax Cable |
507-157 | 157* |
38.0 pF/ft 125 pF/m |
PE & conductive PE | 50 Ω |
PVC-IIA PVC-IIA |
0.725 in 18.4 mm |
TC, GS, TC | 19/24 TC | Coax Cable |
507-158 | 158* |
78.0 pF/ft 256 pF/m |
PE & conductive PE | 25 Ω |
PVC-IIA PVC-IIA |
0.725 in 18.4 mm |
TC, GS, TC | 37/21 TC | Coax Cable |
507-159 | 159 |
29.0 pF/ft 95.1 pF/m |
TFE tape | 50 Ω |
FG-V FG-V |
0.195 in 5.0 mm |
S | 0.0320 S | Coax Cable |
507-16 | 16 |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-I PVC-I |
0.630 in 16.0 mm |
BC | 16.0 mm | Coax Cable |
507-160 | 160 |
12.0 pF/ft 39.4 pF/m |
PE | 125 Ω |
PVC-I PVC-I |
1.055 in 26.80 mm |
BC | 2 cond. 19/27 TC 2 cond. 19/27 BC | Coax Cable |
507-160A | 160A |
12.0 pF/ft 39.4 pF/m |
PE | 125 Ω |
PVC-I PVC-I |
1.055 in 26.80 mm |
BC | 2 cond. 19/27 TC 2 cond. 19/27 BC | Coax Cable |
507-161 | 161 |
20.9 pF/ft 68.6 pF/m |
TFE | 70 Ω |
nylon nylon |
0.082 in 2.1 mm |
S | 7/38 SCB | Coax Cable |
507-162 | 162 |
N/A N/A |
SS TFE | 175 Ω |
None None |
3.065 in 77.85 mm |
BC Tube | 0.156 BC tube | Coax Cable |
507-163 | 163 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-164 | 164* |
22.0 pF/ft 72.2 pF/m |
PE | 75 Ω |
PVC-IIA PVC-IIA |
0.870 in 22.1 mm |
PVC-IIA | 0.1045 BC | Coax Cable |
507-165 | 165* |
29.3 pF/ft 96.1 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.410 in 10.4 mm |
S | 7/20 S | Coax Cable |
507-166 | 166* |
29.3 pF/ft 96.1 pF/m |
TFE | 50 Ω |
FG-V w/armor FG-V w/armor |
0.470 in 11.9 mm |
S | 7/20 S | Coax Cable |
507-167 | 167 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-168 | 168 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-169 | 169 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-17 | 17 |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-II PVC-II |
0.879 in 22.3 mm |
BC | 0.188 BC | Coax Cable |
507-170 | 170 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-171 | 171 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-172 | 172 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-173 | 173 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-174 | 174* |
32.2 pF/ft 106 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.110 in 2.79 mm |
TC | 7/34 CW | Coax Cable |
507-174A | 174A* |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.100 in 2.54 mm |
TC | 7/34 CW | Coax Cable |
507-175 | 175 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Bead supported coaxial line |
507-176 | 176* |
49.0 pF/ft 161 pF/m |
PE | 2240 Ω |
PVC-I PVC-I |
0.405 in 10.3 mm |
BC | 0.135 BC helix | Coax Cable |
507-177 | 177* |
32.2 pF/ft 106 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.895 in 22.7 mm |
2 S | 0.195 BC | Coax Cable |
507-178 | 178 |
32.0 pF/ft 105 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.079 max. in 2.01 max. mm |
S | 7/38 SCW | Coax Cable |
507-178A | 178A* |
32.0 pF/ft 105 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.075 max. in 1.91 max. mm |
S | 7/38 SCW | Coax Cable |
507-178B | 178B* |
32.0 pF/ft 105 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.075 max. in 1.91 max. mm |
S | 7/38 SCW | Coax Cable |
507-179 | 179 |
23.0 pF/ft 75.5 pF/m |
TFE | 75 Ω |
FEP-IX FEP-IX |
0.100 max. in 2.54 max. mm |
S | 7/38 SCCS | Coax Cable |
507-179A | 179A* |
23.0 pF/ft 75.5 pF/m |
TFE | 75 Ω |
FEP-IX FEP-IX |
0.105 max. in 2.67 max. mm |
S | 7/38 SCCS | Coax Cable |
507-179B | 179B* |
23.0 pF/ft 75.5 pF/m |
TFE | 75 Ω |
FEP-IX FEP-IX |
0.105 max. in 2.67 max. mm |
S | 7/38 SCCS | Coax Cable |
507-17A | 17A* |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-IIA PVC-IIA |
0.870 in 22.1 mm |
BC | 0.188 BC | Coax Cable |
507-17B | 17B |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-IIA PVC-IIA |
0.940 in 23.9 mm |
2 S | 0.188 BC | Coax Cable |
507-18 | 18 |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-IA w/armor PVC-IA w/armor |
0.945 in 24.0 mm |
BC | 0.188 BC | Coax Cable |
507-180 | 180 |
15.4 pF/ft 50.5 pF/m |
TFE | 95 Ω |
FEP-IX FEP-IX |
0.141 max. in 3.58 max. mm |
S | 7/38 SCCS | Coax Cable |
507-180A | 180A* |
15.4 pF/ft 50.5 pF/m |
TFE | 95 Ω |
FEP-IX FEP-IX |
0.145 max. in 3.68 max. mm |
S | 7/38 SCCS | Coax Cable |
507-180B | 180B* |
15.4 pF/ft 50.5 pF/m |
TFE | 95 Ω |
FEP-IX FEP-IX |
0.145 max. in 3.68 max. mm |
S | 7/38 SCCS | Coax Cable |
507-181 | 181* |
12.0 pF/ft 39.4 pF/m |
PE | 125 Ω |
PVC-IIA PVC-IIA |
0.640 in 16.3 mm |
BC | 2 cond. 7/26 BC | Coax Cable |
507-182 | 182 |
12.0 each pF/ft 39.4 each pF/m |
PE | 125 each Ω |
PVC-IIA PVC-IIA |
1.055 in 26.8 mm |
2 BC | 2 cond. 19/0.0142 BC 2 cond. 19/0.0066 TC | Coax Cable |
507-183 | 183 |
23.0 pF/ft 75.5 pF/m |
PS helix | 50 Ω |
None None |
0.750 in 19.1 mm |
AL Tube | 0.0251 BC | Coax Cable |
507-184 | 184 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-185 | 185 |
N/A N/A |
Air space PE | 2000 Ω |
PVC-IIA PVC-IIA |
0.282 in 7.16 mm |
Magnet wire | 0.0031 RIM helix | Coax Cable |
507-186 | 186 |
N/A N/A |
SS PE | 1000 Ω |
PVC-IIA PVC-IIA |
0.405 in 10.3 mm |
Magnet wire | 0.0080 TFE Magnet wire helix | Coax Cable |
507-187 | 187 |
19.5 pF/ft 64.0 pF/m |
TFE | 75 Ω |
TFE TFE |
0.110 max. in 2.79 max. mm |
S | 7/38 SCCS | Coax Cable |
507-187A | 187A* |
19.5 pF/ft 64.0 pF/m |
TFE | 75 Ω |
TFE TFE |
0.110 max. in 2.79 max. mm |
S | 7/38 SCCS | Coax Cable |
507-188 | 188* |
29.0 pF/ft 95.1 pF/m |
TFE | 50 Ω |
TFE TFE |
0.110 max. in 2.79 max. mm |
S | 7/0.0067 SCCS | Coax Cable |
507-188A | 188A* |
29.0 pF/ft 95.1 pF/m |
TFE | 50 Ω |
TFE TFE |
0.110 max. in 2.79 max. mm |
S | 7/0.0067 SCCS | Coax Cable |
507-189 | 189 |
23.0 pF/ft 75.5 pF/m |
PS helix | 50 Ω |
PE-IIIA PE-IIIA |
0.875 in 22.2 mm |
2 S | 0.251 BC | Coax Cable |
507-18A | 18A* |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-IIA w/armor PVC-IIA w/armor |
0.945 in 24.0 mm |
BC | 0.188 BC | Coax Cable |
507-19 | 19 |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-II PVC-II |
1.120 in 28.4 mm |
BC | 0.250 BC | Coax Cable |
507-190 | 190* |
50.0 pF/ft 164 pF/m |
Rubber | 50 Ω |
Neoprene® VIII Neoprene® VIII |
0.700 in 17.8 mm |
TC, GS, TC | 19/0.0117 TC | Coax Cable |
507-191 | 191* |
85.0 pF/ft 279 pF/m |
Rubber | 25 Ω |
Neoprene® VIII Neoprene® VIII |
1.460 in 37.1 mm |
TC, GS, TC | TC braid 0.485 | Coax Cable |
507-192 | 192 |
175.0 pF/ft 574.1 pF/m |
Butyl rubber | 12.5 Ω |
Rubber Rubber |
2.165 in 55.0 mm |
TC, GS, GS | TC braid GS tube | Coax Cable |
507-193 | 193 |
159.0 pF/ft 521.7 pF/m |
Silicone rubber | 12.5 Ω |
Rubber Rubber |
2.165 in 55.0 mm |
TC, GS, GS | TC braid GW tube | Coax Cable |
507-194 | 194 |
159.0 pF/ft 521.7 pF/m |
Silicone rubber | 12.5 Ω |
Rubber w/AL armour Rubber w/AL armour |
2.01 max. in 51.1 max. mm |
TC, GS, GS | TC braid GW tube | Coax Cable |
507-195 | 195* |
15.0 pF/ft 49.2 pF/m |
TFE | 95 Ω |
TFE TFE |
0.155 max. in 3.94 max. mm |
S | 7/38 SCCS | Coax Cable |
507-195A | 195A* |
15.0 pF/ft 49.2 pF/m |
TFE | 95 Ω |
TFE TFE |
0.155 max. in 3.94 max. mm |
S | 7/38 SCCS | Coax Cable |
507-196 | 196* |
28.5 pF/ft 93.5 pF/m |
TFE | 50 Ω |
TFE TFE |
0.080 max. in 2.03 max. mm |
S | 7/38 SCCS | Coax Cable |
507-196A | 196A* |
28.5 pF/ft 93.5 pF/m |
TFE | 50 Ω |
TFE TFE |
0.080 max. in 2.03 max. mm |
S | 7/38 SCCS | Coax Cable |
507-197 | 197 |
22.0 pF/ft 72.2 pF/m |
PS helix | 50 Ω |
None None |
0.875 in 22.2 mm |
AL Tube | 0.300 BC | Coax Cable |
507-198 | 198 |
16.0 pF/ft 52.5 pF/m |
PS helix | 70 Ω |
PE PE |
0.600 in 15.2 mm |
AL Tube | 0.114 BC | Coax Cable |
507-199 | 199 |
16.0 pF/ft 52.5 pF/m |
PS helix | 70 Ω |
PE PE |
1.015 in 25.8 mm |
AL Tube | 0.209 BC | Coax Cable |
507-19A | 19A* |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-IIA PVC-IIA |
1.120 in 28.4 mm |
BC | 0.250 BC | Coax Cable |
507-20 | 20 |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-II w/armor PVC-II w/armor |
1.195 in 30.4 mm |
BC | 0.250 BC | Coax Cable |
507-200 | 200 |
16.0 pF/ft 52.5 pF/m |
PS helix | 70 Ω |
PE PE |
1.765 in 44.8 mm |
AL Tube | 0.403 BC | Coax Cable |
507-201 | 201 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Rigid waveguide |
507-202 | 202 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Rigid waveguide |
507-203 | 203 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Rigid waveguide |
507-204 | 204 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Rigid waveguide |
507-205 | 205 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Rigid waveguide |
507-206 | 206 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Rigid waveguide |
507-207 | 207 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Rigid waveguide |
507-208 | 208 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | 19/0.038 S | Rigid waveguide |
507-209 | 209* |
26.5 pF/ft 86.9 pF/m |
Air space TFE | 50 Ω |
Silicone rubber & FG Silicone rubber & FG |
0.750 max. in 19.1 max. mm |
2 S | 19/0.0378 SC | Coax Cable |
507-20A | 20A* |
29.6 pF/ft 97.1 pF/m |
PE | 52 Ω |
PVC-IIA w/armor PVC-IIA w/armor |
1.178 in 29.92 mm |
BC | 0.250 BC | Coax Cable |
507-21 | 21 |
29.0 pF/ft 95.1 pF/m |
PE | 53 Ω |
PVC-II PVC-II |
0.332 in 8.43 mm |
2 S | 0.0508 N | Coax Cable |
507-210 | 210* |
14.5 pF/ft 47.6 pF/m |
Air space TFE | 93 Ω |
FG-V FG-V |
0.242 in 6.15 mm |
S | 0.0253 BC | Coax Cable |
507-211 | 211* |
29.3 pF/ft 96.1 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.730 in 18.5 mm |
BC | 0.190 BC | Coax Cable |
507-211A | 211A* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.730 in 18.5 mm |
BC | 0.190 BC | Coax Cable |
507-212 | 212* |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.332 in 8.4 mm |
2 S | 0.0556 SC | Coax Cable |
507-213 | 213* |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.405 in 10.3 mm |
BC | 7/0.0296 BC | Coax Cable |
507-214 | 214* |
32.2 pF/ft 106 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.425 in 10.8 mm |
2 S | 7/0.0296 SC | Coax Cable |
507-215 | 215* |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PVC-IIA w/ armor PVC-IIA w/ armor |
0.475 in 12.1 mm |
BC | 7/0.0296 BC | Coax Cable |
507-216 | 216* |
22.0 pF/ft 22.0 pF/ft |
PE | 75 Ω |
PVC-IIA PVC-IIA |
0.425 in 10.8 mm |
2 BC | 7/26 TC | Coax Cable |
507-217 | 217* |
32.2 pF/ft 106 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.545 in 13.8 mm |
2 BC | 0.106 BC | Coax Cable |
507-218 | 218* |
32.2 pF/ft 106 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.870 in 22.1 mm |
BC | 0.195 BC | Coax Cable |
507-219 | 219* |
32.2 pF/ft 106 pF/m |
PE | 50 Ω |
PVC-IIA w/ armor PVC-IIA w/ armor |
0.945 max. in 24.0 max. mm |
BC | 0.195 BC | Coax Cable |
507-21A | 21A* |
29.0 pF/ft 95.1 pF/m |
PE | 53 Ω |
PVC-IIA PVC-IIA |
0.332 in 8.43 mm |
2 S | 0.0508 N | Coax Cable |
507-22 | 22 |
18.4 pF/ft 60.4 pF/m |
PE | 95 Ω |
PVC-IIA PVC-IIA |
0.420 in 10.7 mm |
2 TC | 2 cond. 7/0.0152 BC | Coax Cable |
507-220 | 220* |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
1.120 in 28.4 mm |
BC | 0.260 BC | Coax Cable |
507-221 | 221* |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PVC-IIA w/ armor PVC-IIA w/ armor |
1.195 in 30.4 mm |
BC | 0.260 BC | Coax Cable |
507-222 | 222* |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.332 in 8.4 mm |
2 S | 0.0556 resistance | Coax Cable |
507-223 | 223* |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.212 in 5.4 mm |
2 S | 0.035 S | Coax Cable |
507-224 | 224* |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PVC-IIA w/ armor PVC-IIA w/ armor |
0.615 max. in 15.6 max. mm |
2 BC | 0.106 BC | Coax Cable |
507-225 | 225* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.430 in 10.9 mm |
2 S | 7/0.0312 S | Coax Cable |
507-226 | 226* |
29.4 pF/ft 96.5 pF/m |
Taped TFE | 50 Ω |
FG-V FG-V |
0.500 in 12.7 mm |
2 BC | 19/0.0254 S | Coax Cable |
507-227 | 227* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FG-V w/ armor FG-V w/ armor |
0.490 max. in 12.4 max. mm |
2 S | 7/0.0312 S | Coax Cable |
507-228 | 228* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FG-V w/ armor FG-V w/ armor |
0.795 max. in 20.2 max. mm |
BC | 0.190 BC | Coax Cable |
507-228A | 228A* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FG-V w/ armor FG-V w/ armor |
0.795 max. in 20.2 max. mm |
BC | 0.190 BC | Coax Cable |
507-229 | 229 |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.460 in 11.7 mm |
S | 7/20 S | Coax Cable |
507-22A | 22A |
16.3 pF/ft 53.5 pF/m |
PE | 95 Ω |
PVC-IIA PVC-IIA |
0.420 in 10.7 mm |
2 TC | 2 cond. 7/0.0152 BC | Coax Cable |
507-22B | 22B* |
16.3 pF/ft 53.5 pF/m |
PE | 95 Ω |
PVC-IIA PVC-IIA |
0.420 in 10.7 mm |
2 TC | 2 cond. 7/0.0152 BC | Coax Cable |
507-23 | 23 |
13.0 pF/ft 42.7 pF/m |
PE | 125 Ω |
PVC-I PVC-I |
0.650 x 0.945 in 16.5 x 24.0 mm |
2 BC | 2 cond. 7/21 BC | Coax Cable |
507-230 | 230* |
100.0 pF/ft 328.1 pF/m |
Rubber | 25 Ω |
Rubber-IV Rubber-IV |
0.740 in 18.8 mm |
TC, GS, GS | 37/21 TC | Coax Cable |
507-231 | 231 |
25.0 pF/ft 82.0 pF/m |
PE foam | 50 Ω |
None None |
0.500 in 12.7 mm |
Al tube | 0.162 BC tube | Coax Cable |
507-231A | 231A |
25.0 pF/ft 82.0 pF/m |
PE foam | 50 Ω |
None None |
0.500 in 12.7 mm |
Al tube | 0.162 BC | Coax Cable |
507-232 | 232 |
22.0 pF/ft 72.2 pF/m |
PE helix | 50 Ω |
PE-IIIA PE-IIIA |
1.015 in 25.78 mm |
Al tube | 0.300 BC | Coax Cable |
507-233 | 233 |
22.0 pF/ft 72.2 pF/m |
PS helix | 50 Ω |
PE-IIIA PE-IIIA |
1.765 in 44.83 mm |
Al tube | BC tube | Coax Cable |
507-234 | 234 |
22.0 pF/ft 72.2 pF/m |
PS helix | 50 Ω |
PE-IIIA PE-IIIA |
3.295 in 83.69 mm |
Al tube | BC tube | Coax Cable |
507-235 | 235* |
29.5 pF/ft 96.8 pF/m |
TFE tape | 50 Ω |
Silicone rubber Silicone rubber |
0.470 max. in 11.9 max. mm |
2 S | 7/21 S | Coax Cable |
507-236 | 236 |
24.0 pF/ft 78.7 pF/m |
PS helix | 50 Ω |
None None |
0.500 in 12.7 mm |
Al tube | 0.162 BC | Coax Cable |
507-237 | 237 |
24.0 pF/ft 78.7 pF/m |
PS helix | 50 Ω |
PE-IIIA PE-IIIA |
0.600 in 15.2 mm |
Al tube | 0.162 BC | Coax Cable |
507-238 | 238 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Coax Cable |
507-239 | 239 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Coax Cable |
507-23A | 23A* |
13.0 pF/ft 42.7 pF/m |
PE | 125 Ω |
PVC-IIA PVC-IIA |
0.650 x 0.945 in 16.5 x 24.0 mm |
2 BC | 2 cond. 7/21 BC | Coax Cable |
507-24 | 24 |
13.0 pF/ft 42.7 pF/m |
PE | 125 Ω |
PVC-I w/armor PVC-I w/armor |
0.735 x 1.034 in 18.7 x 26.3 mm |
2 BC | 2 cond. 7/21 BC | Coax Cable |
507-240 | 240 |
22.0 pF/ft 72.2 pF/m |
PS helix | 50 Ω |
None None |
1.625 in 41.28 mm |
Al tube | BC tube | Coax Cable |
507-241 | 241 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Coax Cable |
507-242 | 242 |
22.0 pF/ft 72.2 pF/m |
PS helix | 50 Ω |
None None |
3.125 in 79.38 mm |
Al tube | BC tube | Coax Cable |
507-243 | 243 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Coax Cable |
507-244 | 244 |
15.5 pF/ft 50.9 pF/m |
PS helix | 75 Ω |
None None |
0.500 in 12.70 mm |
Al tube | 0.102 BC | Coax Cable |
507-245 | 245 |
15.5 pF/ft 50.9 pF/m |
PS helix | 75 Ω |
PE-IIIA PE-IIIA |
0.600 in 15.24 mm |
Al tube | 0.102 BC | Coax Cable |
507-246 | 246 |
15.5 pF/ft 50.9 pF/m |
PS helix | 75 Ω |
None None |
0.875 in 22.23 mm |
Al tube | 0.188 BC | Coax Cable |
507-247 | 247 |
15.5 pF/ft 50.9 pF/m |
PS helix | 75 Ω |
PE-IIIA PE-IIIA |
1.015 in 25.78 mm |
Al tube | 0.188 BC | Coax Cable |
507-248 | 248 |
15.0 pF/ft 49.2 pF/m |
PS helix | 75 Ω |
None None |
1.625 in 41.28 mm |
Al tube | 0.370 BC | Coax Cable |
507-249 | 249 |
15.0 pF/ft 49.2 pF/m |
PS helix | 75 Ω |
PE-IIIA PE-IIIA |
1.765 in 44.83 mm |
Al tube | 0.370 BC | Coax Cable |
507-24A | 24A* |
13.0 pF/ft 42.7 pF/m |
PE | 125 Ω |
PVC-IIA w/armor PVC-IIA w/armor |
0.735 x 1.034 in 18.7 x 26.3 mm |
2 BC | 2 cond. 7/21 BC | Coax Cable |
507-25 | 25* |
50.0 pF/ft 164 pF/m |
Rubber | 48 Ω |
Rubber-IV Rubber-IV |
0.505 in 12.8 mm |
2 TC | 19/0.0117 TC | Coax Cable |
507-250 | 250 |
15.0 pF/ft 49.2 pF/m |
PS helix | 75 Ω |
None None |
3.125 in 79.38 mm |
Al tube | 0.732 BC | Coax Cable |
507-251 | 251 |
15.0 pF/ft 49.2 pF/m |
PS helix | 75 Ω |
PE-IIIA PE-IIIA |
3.295 in 83.69 mm |
Al tube | 0.732 BC | Coax Cable |
507-252 | 252 |
24.4 pF/ft 80.1 pF/m |
PE tube | 75 Ω |
None None |
0.530 in 13.46 mm |
Al tube | 0.167 BC | Coax Cable |
507-253 | 253 |
24.4 pF/ft 80.1 pF/m |
PE tube | 75 Ω |
PE PE |
0.635 max. in 16.1 max. mm |
Al tube | 0.167 BC | Coax Cable |
507-254 | 254 |
24.4 pF/ft 80.1 pF/m |
PE tube | 50 Ω |
PE PE |
1.100 max. in 27.94 max. mm |
Al tube | 0.311 BC | Coax Cable |
507-255 | 255 |
24.4 pF/ft 80.1 pF/m |
PE tube | 50 Ω |
None None |
0.953 in 24.21 mm |
Al tube | 0.311 BC | Coax Cable |
507-256 | 256 |
23.5 pF/ft 77.1 pF/m |
TFE tube | 50 Ω |
None None |
0.953 in 24.21 mm |
Al tube | S tube | Coax Cable |
507-257 | 257 |
24.4 pF/ft 80.1 pF/m |
PS tube | 50 Ω |
None None |
1.786 in 45.36 mm |
Al tube | BC tube | Coax Cable |
507-258 | 258 |
24.4 pF/ft 80.1 pF/m |
PE tube | 50 Ω |
PE PE |
1.936 max. in 49.17 max. mm |
Al tube | BC tube | Coax Cable |
507-259 | 259 |
23.5 pF/ft 77.1 pF/m |
TFE tube | 50 Ω |
None None |
0.390 in 9.91 mm |
Al tube | 0.115 BC | Coax Cable |
507-25A | 25A* |
50.0 pF/ft 164 pF/m |
Rubber | 48 Ω |
Rubber-IV Rubber-IV |
0.505 in 12.8 mm |
2 TC | 19/0.0117 TC | Coax Cable |
507-26 | 26* |
50.0 pF/ft 164 pF/m |
Rubber | 48 Ω |
Rubber-IV w/armor Rubber-IV w/armor |
0.525 in 13.3 mm |
TC | 19/0.0117 TC | Coax Cable |
507-260 | 260 |
23.5 pF/ft 77.1 pF/m |
PE tube | 50 Ω |
PE-IIIA PE-IIIA |
0.450 in 11.4 mm |
Al tube | 0.115 BC | Coax Cable |
507-261 | 261 |
23.5 pF/ft 77.1 pF/m |
PE tube | 50 Ω |
None None |
3.370 in 85.60 mm |
Al tube | BC tube | Coax Cable |
507-262 | 262 |
23.5 pF/ft 77.1 pF/m |
PE tube | 50 Ω |
PE PE |
3.520 in 89.41 mm |
Al tube | BC tube | Coax Cable |
507-263 | 263 |
21.5 pF/ft 70.5 pF/m |
Air space TFE | 50 Ω |
None None |
0.500 in 12.7 mm |
Al tube | 0.172 BC | Coax Cable |
507-264 | 264 |
38.0 pF/ft 125 pF/m |
PE | 40 Ω |
PVC-IIA PVC-IIA |
0.750 in 19.1 mm |
2 BC 2 TC | 4 x 19/27 BC | Coax Cable |
507-264A | 264A |
38.0 pF/ft 125 pF/m |
PE | 40 Ω |
PU PU |
0.750 in 19.1 mm |
2 BC 2 TC | 4 x 19/27 BC | Coax Cable |
507-264B | 264B |
42.0 max. pF/ft 138 max. pF/m |
PE | 40 Ω |
PU PU |
0.750 in 19.1 mm |
2 BC 2 TC | 4 x 19/27 BC | Coax Cable |
507-264C | 264C |
42.0 max. pF/ft 138 max. pF/m |
PE | 40 Ω |
PU PU |
0.750 in 19.1 mm |
2 BC 2 TC | 2 x 13 BC 2 x 13 TC | Coax Cable |
507-265 | 265 |
22.3 pF/ft 73.2 pF/m |
PS helix | 50 Ω |
PE-IIIA PE-IIIA |
2.070 in 52.58 mm |
CCS tube | BC tube | Coax Cable |
507-266 | 266* |
53.0 pF/ft 174 pF/m |
PE | 1530 Ω |
PVC-I PVC-I |
0.400 in 10.2 mm |
BC | 0.144 BC helix | Coax Cable |
507-267 | 267 |
22.2 pF/ft 72.8 pF/m |
PS helix | 50 Ω |
PE-III PE-III |
1.190 in 30.23 mm |
CCS tube | BC tube | Coax Cable |
507-268 | 268 |
23.0 pF/ft 75.5 pF/m |
PS helix | 50 Ω |
None None |
0.500 in 12.7 mm |
BC Tube | 0.160 BC | Coax Cable |
507-269 | 269 |
22.2 pF/ft 72.8 pF/m |
PS helix | 50 Ω |
None None |
1.005 in 25.53 mm |
BC Tube | BC tube | Coax Cable |
507-26A | 26A* |
50.0 pF/ft 164 pF/m |
Rubber | 48 Ω |
Rubber-IV w/armor Rubber-IV w/armor |
0.505 in 12.8 mm |
TC | 19/0.0117 TC | Coax Cable |
507-27 | 27 |
50.0 pF/ft 164 pF/m |
Rubber | 48 Ω |
PVC-II PVC-II |
0.675 in 17.1 mm |
TC | 19/0.0185 TC | Coax Cable |
507-270 | 270 |
22.3 pF/ft 73.2 pF/m |
PS helix | 50 Ω |
None None |
1.830 in 46.48 mm |
BC Tube | BC tube | Coax Cable |
507-271 | 271 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-272 | 272 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-273 | 273 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-274 | 274 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-275 | 275 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-276 | 276 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-277 | 277 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-278 | 278 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-279 | 279* |
17.0 pF/ft 55.8 pF/m |
Air space TFE | 75 Ω |
FG-V FG-V |
0.145 in 3.68 mm |
S | 19/36 SCCS | Coax Cable |
507-27A | 27A* |
50.0 pF/ft 164 pF/m |
Rubber | 48 Ω |
Rubber-IV w/armor Rubber-IV w/armor |
0.670 in 17.0 mm |
TC | 19/0.0185 TC | Coax Cable |
507-28 | 28 |
50.0 pF/ft 164 pF/m |
Rubber | 50 Ω |
Rubber-IV Rubber-IV |
0.805 in 20.4 mm |
TC GS |
19/0.0185 TC | Coax Cable |
507-280 | 280* |
25.4 pF/ft 83.3 pF/m |
Taped TFE | 50 Ω |
FEP-IX FEP-IX |
0.480 in 12.2 mm |
2 S | 0.1144 BC | Coax Cable |
507-281 | 281 |
25.4 pF/ft 83.3 pF/m |
Taped TFE | 50 Ω |
SR & braid SR & braid |
0.750 in 19.1 mm |
2 S | 19/0.0378 S | Coax Cable |
507-282 | 282 |
28.2 pF/ft 92.5 pF/m |
Irradiated PE | 54.6 Ω |
FEP FEP |
0.200 in 5.08 mm |
2 S | 0.0253 S | Coax Cable |
507-283 | 283 |
50.0 pF/ft 164 pF/m |
Rubber | 46 Ω |
Rubber-IV Rubber-IV |
0.475 max. in 12.1 max. mm |
2 S | 19/0.177 S | Coax Cable |
507-284A | 284A |
15.0 pF/ft 49.2 pF/m |
PE helix | 75 Ω |
None None |
1.005 in 25.53 mm |
BC Tube | 0.220 BC | Coax Cable |
507-285A | 285A |
13.0 pF/ft 42.7 pF/m |
TFE helix | 100 Ω |
None None |
1.005 in 25.53 mm |
BC Tube | 0.1140 BC | Coax Cable |
507-286 | 286 |
15.1 pF/ft 49.5 pF/m |
PE helix | 75 Ω |
None None |
1.830 in 46.48 mm |
BC Tube | BC tube | Coax Cable |
507-287 | 287 |
13.5 pF/ft 44.3 pF/m |
PE helix | 100 Ω |
None None |
1.830 in 46.48 mm |
BC Tube | 0.197 BC | Coax Cable |
507-288 | 288 |
21.6 pF/ft 70.9 pF/m |
PE helix | 50 Ω |
None None |
3.750 in 95.25 mm |
CCS tube | BC tube | Coax Cable |
507-289 | 289 |
14.7 pF/ft 48.2 pF/m |
PE helix | 75 Ω |
None None |
3.750 in 95.25 mm |
CCS tube | CCS tube | Coax Cable |
507-28A | 28A |
50.0 pF/ft 164 pF/m |
Rubber | 50 Ω |
Rubber-IV w/armor Rubber-IV w/armor |
0.805 in 20.4 mm |
TC | 19/0.0185 TC | Coax Cable |
507-28B | 28B* |
50.0 pF/ft 164 pF/m |
Rubber | 48 Ω |
Rubber-IV Rubber-IV |
0.750 max. in 19.1 max. mm |
TC GS |
19/0.0185 TC | Coax Cable |
507-29 | 29 |
28.5 pF/ft 93.5 pF/m |
PE | 53.5 Ω |
PE-III PE-III |
0.184 in 4.67 mm |
TC | 0.0320 BC | Coax Cable |
507-290 | 290 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-291 | 291 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-292 | 292 |
15.1 pF/ft 49.5 pF/m |
PE helix | 75 Ω |
PE FC PE FC |
1.830 in 46.48 mm |
BC Tube | BC tube | Coax Cable |
507-293 | 293 |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PE-IIIA PE-IIIA |
0.545 in 13.8 mm |
S | 0.106 BC | Coax Cable |
507-293A | 293A |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PE-IIIA PE-IIIA |
0.545 in 13.8 mm |
S | 0.106 BC | Coax Cable |
507-294 | 294 |
16.3 pF/ft 53.5 pF/m |
PE | 95 Ω |
PE-IIIA PE-IIIA |
0.630 in 16.0 mm |
TC | 0.0808 BC 0.0808 TC | Coax Cable |
507-294A | 294A |
16.3 pF/ft 53.5 pF/m |
PE | 95 Ω |
PE-IIIA PE-IIIA |
0.630 in 16.0 mm |
S | 0.0808 BC 0.0808 TC | Coax Cable |
507-295 | 295 |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PE-IIIA PE-IIIA |
0.895 in 22.7 mm |
S | 0.195 BC | Coax Cable |
507-296 | 296* |
36.4 pF/ft 119 pF/m |
Silicone rubber | 50 Ω |
Neoprene® Neoprene® |
1.190 in 30.23 mm |
S | 37/0.0336 S | Coax Cable |
507-297 | 297 |
21.4 pF/ft 70.2 pF/m |
TFE helix | 50 Ω |
None None |
1.005 in 25.53 mm |
BC Tube | BC tube | Coax Cable |
507-298 | 298 |
N/A N/A |
PE | N/A |
PE foam PE foam |
0.650 in 16.5 mm |
None | 7/24 CCS | Coax Cable |
507-30 | 30 |
27.0 pF/ft 88.6 pF/m |
Copo. | 50 Ω |
PVC-I PVC-I |
0.250 in 6.35 mm |
BC | 7/26 BC | Coax Cable |
507-301 | 301* |
32.0 pF/ft 105 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.245 in 6.22 mm |
HR | 7/0.0203 HR | Coax Cable |
507-302 | 302* |
19.5 pF/ft 64.0 pF/m |
TFE | 75 Ω |
FEP-IX FEP-IX |
0.206 max. in 5.23 max. mm |
S | 0.025 SCCS | Coax Cable |
507-303 | 303* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.170 in 4.32 mm |
S | 0.039 SCCS | Coax Cable |
507-304 | 304* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.280 in 7.11 mm |
2 S | 0.059 SCCS | Coax Cable |
507-305 | 305 |
19.5 pF/ft 64.0 pF/m |
FEP | 75 Ω |
PE-IIIA PE-IIIA |
1.990 in 50.55 mm |
BC Tube | BC tube | Coax Cable |
507-306A | 306A |
16.9 pF/ft 55.4 pF/m |
PE foam | 75 Ω |
PE-IIIA PE-IIIA |
1.015 in 25.78 mm |
AL Tube | 0.173 BC | Coax Cable |
507-307A | 307A* |
16.7 pF/ft 54.8 pF/m |
PE foam | 75 Ω |
PE-IIIA PE-IIIA |
0.270 max. in 6.86 max. mm |
2 S | 19/0.0058 S | Coax Cable |
507-31 | 31 |
31.0 pF/ft 102 pF/m |
Copo. | 51 Ω |
PVC-I PVC-I |
0.405 in 10.3 mm |
BC | 7/21 BC | Coax Cable |
507-316 | 316* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.098 in 2.49 mm |
S | 7/0.0067 SCCS | Coax Cable |
507-317 | 317 |
15.4 pF/ft 50.5 pF/m |
FEP | 95 Ω |
Neoprene® Neoprene® |
0.710 in 18.0 mm |
TC | 2 cond. 7/0.029 BC | Coax Cable |
507-318 | 318 |
22.2 pF/ft 72.8 pF/m |
PE helix | 50 Ω |
PE-IIIA PE-IIIA |
1.100 in 27.94 mm |
BC Tube | BC tube O.D. 0.3580 I.D. 0.2870 | Coax Cable |
507-319 | 319 |
22.3 pF/ft 73.2 pF/m |
SS PS | 50 Ω |
PE-IIIA PE-IIIA |
1.970 in 50.04 mm |
BC Tube | BC tube O.D. 0.6880 I.D. 0.5880 | Coax Cable |
507-32 | 32 |
29.0 pF/ft 95.1 pF/m |
Copo. | 51 Ω |
PVC-I w/armor PVC-I w/armor |
0.465 in 11.8 mm |
BC | 7/21 BC | Coax Cable |
507-321 | 321 |
21.7 pF/ft 71.2 pF/m |
SS PE | 50 Ω |
None None |
2.850 in 72.39 mm |
BC Tube | BC tube | Coax Cable |
507-322 | 322 |
21.7 pF/ft 71.2 pF/m |
SS PE | 50 Ω |
PE FC PE FC |
3.040 in 77.22 mm |
BC Tube | BC tube | Coax Cable |
507-323 | 323 |
25.6 pF/ft 84.0 pF/m |
PE foam | 50 Ω |
PE FC PE FC |
1.060 in 26.92 mm |
BC Tube | BC tube | Coax Cable |
507-324 | 324 |
25.6 pF/ft 84.0 pF/m |
PE foam | 50 Ω |
None None |
0.980 in 24.9 mm |
BC Tube | BC tube | Coax Cable |
507-325 | 325 |
26.3 pF/ft 86.3 pF/m |
PE spline | 50 Ω |
PU PU |
0.465 max. in 11.8 max. mm |
2 SC strip | 19/0.0200 SCCA | Coax Cable |
507-326 | 326 |
26.3 pF/ft 86.3 pF/m |
PE spline | 50 Ω |
PU PU |
0.779 max. in 19.8 max. mm |
2 SC strip | 19/0.0400 SCCA | Coax Cable |
507-327 | 327 |
26.3 pF/ft 86.3 pF/m |
PE spline | 50 Ω |
PU PU |
1.18 max. in 30.0 max. mm |
2 SC strip | 19/0.0640 SCCA | Coax Cable |
507-328 | 328* |
85.0 pF/ft 278.9 pF/m |
Rubbere | 25 Ω |
Neoprene® Neoprene® |
1.460 in 37.08 mm |
TC, GS, TC | TC braid | Coax Cable |
507-329 | 329* |
50.0 pF/ft 164 pF/m |
Rubber | 50 Ω |
Neoprene® Neoprene® |
0.700 in 17.8 mm |
TC, GS, TC | 19/0.0117 TC | Coax Cable |
507-33 | 33 |
30.0 pF/ft 98.4 pF/m |
PE | 51 Ω |
Lead Lead |
0.470 in 11.9 mm |
None | 0.1019 BC | Coax Cable |
507-330 | 330 |
25.0 pF/ft 82.0 pF/m |
PE foam | 50 Ω |
None None |
0.242 in 6.15 mm |
SC | SC | Coax Cable |
507-331 | 331 |
25.0 pF/ft 82.0 pF/m |
PE foam | 50 Ω |
PE-IIIA PE-IIIA |
0.625 in 15.9 mm |
Al tube | 0.162 BC | Coax Cable |
507-332 | 332 |
25.0 pF/ft 82.0 pF/m |
PE foam | 50 Ω |
None None |
0.875 in 22.2 mm |
Al tube | 0.288 BC | Coax Cable |
507-333 | 333 |
25.0 pF/ft 82.0 pF/m |
PE foam | 50 Ω |
PE-IIIA PE-IIIA |
1.052 max. in 26.72 max. mm |
Al tube | 0.288 BC | Coax Cable |
507-334 | 334 |
17.0 pF/ft 55.8 pF/m |
PE foam | 75 Ω |
None None |
0.500 in 12.7 mm |
Al tube | 0.098 BC | Coax Cable |
507-335 | 335 |
17.0 pF/ft 55.8 pF/m |
PE foam | 75 Ω |
PE-IIIA PE-IIIA |
0.625 in 15.9 mm |
Al tube | 0.098 BC | Coax Cable |
507-336 | 336 |
16.5 pF/ft 54.1 pF/m |
PE foam | 75 Ω |
None None |
0.875 in 22.2 mm |
Al tube | 0.173 BC | Coax Cable |
507-34 | 34 |
21.5 pF/ft 70.5 pF/m |
PE | 71 Ω |
PVC-I PVC-I |
0.625 in 15.9 mm |
BC | 7/21 BC | Coax Cable |
507-34A | 34A |
21.5 pF/ft 70.5 pF/m |
PE | 71 Ω |
PVC-IIA PVC-IIA |
0.630 in 16.0 mm |
BC | 7/0.0249 BC | Coax Cable |
507-34B | 34B* |
21.5 pF/ft 70.5 pF/m |
PE | 75 Ω |
PVC-IIA PVC-IIA |
0.630 in 16.0 mm |
BC | 7/.0249 BC | Coax Cable |
507-35 | 35 |
22.0 pF/ft 72.2 pF/m |
PE | 75 Ω |
PVC-II w/armor PVC-II w/armor |
0.945 in 24.0 mm |
BC | 0.1144 BC | Coax Cable |
507-35A | 35A |
22.0 pF/ft 72.2 pF/m |
PE | 75 Ω |
PVC-IIA w/armor PVC-IIA w/armor |
0.945 in 24.0 mm |
BC | 0.1045 BC | Coax Cable |
507-35B | 35B* |
22.0 pF/ft 72.2 pF/m |
PE | 75 Ω |
PVC-IIA w/armor PVC-IIA w/armor |
0.945 max. in 24.0 max. mm |
BC | 0.1045 BC | Coax Cable |
507-36 | 36 |
22.0 pF/ft 72.2 pF/m |
PE | 69 Ω |
PVC-I PVC-I |
1.180 in 29.97 mm |
BC | 0.1620 BC | Coax Cable |
507-360 | 360 |
25.0 pF/ft 82.0 pF/m |
PE foam | 50 Ω |
PE-IIIA PE-IIIA |
0.825 in 21.0 mm |
Al tube | 0.243 BC | Coax Cable |
507-366 | 366 |
26.6 pF/ft 87.3 pF/m |
PE foam | 50 Ω |
PE-IIIA PE-IIIA |
0.620 in 15.7 mm |
BC Tube | 0.160 BC | Coax Cable |
507-367 | 367 |
21.7 pF/ft 71.2 pF/m |
PE helix | 50 Ω |
PE-IIIA PE-IIIA |
5.200 in 132.1 mm |
BC Tube | BC tube | Coax Cable |
507-369 | 369 |
23.5 pF/ft 77.1 pF/m |
PE tubes | 50 Ω |
PE-IIIA PE-IIIA |
0.470 in 11.9 mm |
Al tube | 0.177 BC | Coax Cable |
507-37 | 37 |
38.0 pF/ft 125 pF/m |
Rubber-C | 52.5 Ω |
PE-III PE-III |
0.210 in 5.33 mm |
TC | 0.0320 TC | Coax Cable |
507-370 | 370 |
24.0 pF/ft 78.7 pF/m |
PE tubes | 50 Ω |
None None |
0.390 in 9.91 mm |
Al tube | 0.177 BC | Coax Cable |
507-373 | 373 |
N/A N/A |
PE | N/A |
PE foam PE foam |
0.650 in 16.5 mm |
None | 0.0508 BC | Coax Cable |
507-374 | 374 |
N/A N/A |
PE | N/A |
PE foam PE foam |
0.650 in 16.5 mm |
None | 0.0285 BC | Coax Cable |
507-376 | 376 |
26.0 pF/ft 85.3 pF/m |
PE foam | 50 Ω |
PE-IIIA PE-IIIA |
1.060 in 26.9 mm |
Al tube | 0.312 BC tube | Coax Cable |
507-377 | 377 |
24.0 pF/ft 78.7 pF/m |
TFE tubes | 50 Ω |
None None |
0.530 in 13.5 mm |
Al tube | 0.165 S tube | Coax Cable |
507-378 | 378 |
22.1 pF/ft 72.5 pF/m |
PE helix | 50 Ω |
PE-IIIA PE-IIIA |
2.000 in 50.8 mm |
Al tube | BC tube | Coax Cable |
507-38 | 38 |
38.0 pF/ft 125 pF/m |
Rubber-C | 52.5 Ω |
PE-III PE-III |
0.312 in 7.92 mm |
2 TC | 0.0453 TC | Coax Cable |
507-382 | 382 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Rigid Line |
507-383 | 383 |
N/A N/A |
PE | 100 Ω |
PE foam PE foam |
0.650 in 16.5 mm |
None | 2 cond. 0.0403 | Coax Cable |
507-384 | 384 |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PE foam PE foam |
0.650 in 16.5 mm |
Flat BC | 0.16 BC | Coax Cable |
507-385 | 385 |
25.4 pF/ft 83.3 pF/m |
SS TFE | 50 Ω |
Optional Optional |
0.660 in 16.8 mm |
AL Tube | 0.153 S | Coax Cable |
507-386 | 386 |
N/A N/A |
PE | N/A |
PE foam PE foam |
0.650 in 16.5 mm |
None | 0.0508 CCS | Coax Cable |
507-388 | 388 |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PE-IIIA PE-IIIA |
0.545 in 13.8 mm |
S | 0.1020 BC | Coax Cable |
507-389 | 389 |
22.8 pF/ft 74.8 pF/m |
PE | 50 Ω |
PE-IIIA PE-IIIA |
0.875 in 22.2 mm |
2S | 0.250 BC AL | Coax Cable |
507-39 | 39 |
28.6 pF/ft 93.8 pF/m |
Rubber-C | 72.5 Ω |
PE-III PE-III |
0.312 in 7.92 mm |
2 TC | 0.0253 TCW | Coax Cable |
507-391 | 391* |
23.0 pF/ft 75.5 pF/m |
C PE & PE | 72 Ω |
PVC-IIA PVC-IIA |
0.405 in 10.3 mm |
TC | 7/26 TC | Coax Cable |
507-392 | 392* |
23.0 pF/ft 75.5 pF/m |
C PE & PE | 72 Ω |
PVC-IIA PVC-IIA |
0.475 in 12.1 mm |
TC | 7/26 TC | Coax Cable |
507-393 | 393* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.390 in 9.9 mm |
2 S | 7/0.0312 S | Coax Cable |
507-4 | 4 |
30.0 pF/ft 98.4 pF/m |
PE | 50 Ω |
PVC-I PVC-I |
0.226 in 5.74 mm |
2 BC | 0.0320 BC | Coax Cable |
507-40 | 40 |
28.0 pF/ft 91.9 pF/m |
Rubber-C | 72.5 Ω |
Rubber-IV Rubber-IV |
0.420 in 10.7 mm |
2 TC | 0.0253 TCW | Coax Cable |
507-400 | 400* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.195 in 4.95 mm |
2 S | 19/0.0077 S | Coax Cable |
507-401 | 401* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
None None |
0.250 in 6.35 mm |
BC Tube | 0.0641 S | Coax Cable |
507-402 | 402* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
None None |
0.141 in 3.58 mm |
BC Tube | 0.0360 SCCS | Coax Cable |
507-403 | 403* |
29.4 pF/ft 96.5 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.104 in 2.64 mm |
2 S | 7/38 SCCS | Coax Cable |
507-404 | 404* |
31.5 pF/ft 103 pF/m |
TFE | 50 Ω |
FEP-IX FEP-IX |
0.075 max. in 0.191 max. mm |
S | 7/38 SCCS | Coax Cable |
507-405 | 405* |
50 Ω 96.5 pF/m |
TFE | 50 Ωx |
None None |
0.086 in 2.18 mm |
BC Tube | 0.0201 SCCS | Coax Cable |
507-41 | 41 |
27.6 pF/ft 90.6 pF/m |
Rubber-C | 67.5 Ω |
Rubber-IV Rubber-IV |
0.425 in 10.8 mm |
TC | 16/30 TC | Coax Cable |
507-42 | 42 |
20.0 pF/ft 65.6 pF/m |
PE | 78.6 Ω |
PVC-II PVC-II |
0.342 in 8.69 mm |
2 S | 0.0285 N | Coax Cable |
507-43 | 43 |
17.6 pF/ft 57.7 pF/m |
Rubber-B | 95 Ω |
PVC-I PVC-I |
0.617 in 15.7 mm |
BC | 2 cond. 7/21 BC | Coax Cable |
507-44 | 44 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Stub supported coaxial |
507-45 | 45 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Stub supported coaxial |
507-46 | 46 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Stub supported coaxial |
507-47 | 47 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Stub supported coaxial |
507-48 | 48 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-49 | 49 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-5 | 5 |
28.5 pF/ft 93.5 pF/m |
PE | 52.5 Ω |
PVC-I PVC-I |
0.332 in 8.43 mm |
2 BC | 0.0508 BC | Coax Cable |
507-50 | 50 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-51 | 51 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-52 | 52 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-53 | 53 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-54 | 54 |
27.0 pF/ft 88.6 pF/m |
PE | 58 Ω |
PVC-I PVC-I |
0.275 in 7.0 mm |
BC | 7/26 BC | Coax Cable |
507-54A | 54A |
26.5 pF/ft 86.9 pF/m |
PE | 58 Ω |
PE-III PE-III |
0.250 in 6.4 mm |
TC | 7/.0152 BC | Coax Cable |
507-55 | 55 |
28.5 pF/ft 93.5 pF/m |
PE | 53.5 Ω |
PE-III PE-III |
0.200 in 5.1 mm |
2 TC | 0.320 BC | Coax Cable |
507-55A | 55A |
28.5 pF/ft 93.5 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.200 in 5.1 mm |
2 S | 0.035 S | Coax Cable |
507-55B | 55B* |
28.5 pF/ft 93.5 pF/m |
PE | 53 Ω |
PE-III PE-III |
0.200 max. in 5.08 max. mm |
2 TC | 0.032 S | Coax Cable |
507-56 | 56 |
50.0 pF/ft 164 pF/m |
Rubber-C | 48 Ω |
PVC-I PVC-I |
0.535 in 13.6 mm |
2 BC | 19/.0117 BC | Coax Cable |
507-57 | 57 |
17.0 pF/ft 55.8 pF/m |
PE | 95 Ω |
PVC-I PVC-I |
0.625 in 15.9 mm |
TC | 2 cond. 7/21 BC | Coax Cable |
507-57A | 57A* |
17.0 pF/ft 55.8 pF/m |
PE | 95 Ω |
PVC-IIA PVC-IIA |
0.625 in 15.9 mm |
TC | 2 cond. 7/21 BC | Coax Cable |
507-58 | 58 |
28.5 pF/ft 93.5 pF/m |
PE | 53.5 Ω |
PVC-I PVC-I |
0.195 in 4.95 mm |
TC | 0.0320 BC | Coax Cable |
507-58A | 58A |
32.2 pF/ft 106 pF/m |
PE | 50 Ω |
PVC-I PVC-I |
0.195 in 4.95 mm |
TC | 19/33 TC | Coax Cable |
507-58B | 58B |
28.5 pF/ft 93.5 pF/m |
PE | 53.5 Ω |
PVC-IIA PVC-IIA |
0.195 in 4.95 mm |
TC | 0.0320 BC | Coax Cable |
507-58C | 58C* |
32.2 pF/ft 106 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.195 in 4.95 mm |
TC | 19/33 TC | Coax Cable |
507-59 | 59 |
22.0 pF/ft 72.2 pF/m |
PE | 73 Ω |
PVC-II PVC-II |
0.242 in 6.15 mm |
BC | 0.0226 CW | Coax Cable |
507-59A | 59A |
22.0 pF/ft 72.2 pF/m |
PE | 75 Ω |
PVC-IIA PVC-IIA |
0.242 in 6.15 mm |
BC | 0.0226 CW | Coax Cable |
507-59B | 59B* |
22.0 pF/ft 72.2 pF/m |
PE | 75 Ω |
PVC-IIA PVC-IIA |
0.242 in 6.15 mm |
BC | 0.0226 CW | Coax Cable |
507-5A | 5A |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PVC-II PVC-II |
0.328 in 8.33 mm |
2 S | 0.0508 S | Coax Cable |
507-5B | 5B* |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.338 in 8.59 mm |
2 S | 0.0508 S | Coax Cable |
507-6 | 6 |
22.0 pF/ft 72.2 pF/m |
PE | 75 Ω |
PVC-II PVC-II |
0.332 in 8.43 mm |
BC-S | 0.0285 CW | Coax Cable |
507-60 | 60 |
39.0 pF/ft 128 pF/m |
Rubber | 50 Ω |
Rubber-IV Rubber-IV |
0.425 in 10.8 mm |
BC | 0.0508 stranded BC | Coax Cable |
507-61 | 61 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Special 500 ohm line |
507-62 | 62 |
14.5 pF/ft 47.6 pF/m |
Air space PE | 93 Ω |
PVC-IIA PVC-IIA |
0.242 in 6.15 mm |
BC | 0.0253 CW | Coax Cable |
507-62A | 62A* |
14.5 pF/ft 47.6 pF/m |
Air space PE | 93 Ω |
PVC-IIA PVC-IIA |
0.242 in 6.15 mm |
BC | 0.0253 CW | Coax Cable |
507-62B | 62B |
14.5 pF/ft 47.6 pF/m |
Air space PE | 93 Ω |
PVC-IIA PVC-IIA |
0.242 in 6.15 mm |
BC | 7/32 CW | Coax Cable |
507-63 | 63 |
11.0 pF/ft 36.1 pF/m |
Air space PE | 125 Ω |
PVC-IIA PVC-IIA |
0.405 in 10.3 mm |
BC | 0.0253 CW | Coax Cable |
507-63A | 63A |
11.0 pF/ft 36.1 pF/m |
Air space PE | 125 Ω |
PVC-IIA PVC-IIA |
0.405 in 10.3 mm |
BC | 0.0253 BC | Coax Cable |
507-63B | 63B* |
11.0 pF/ft 36.1 pF/m |
Air space PE | 125 Ω |
PVC-IIA PVC-IIA |
0.405 in 10.3 mm |
BC | 0.0253 CW | Coax Cable |
507-64 | 64* |
50.0 pF/ft 164 pF/m |
Rubber-IV | 48 Ω |
Rubber-IV Rubber-IV |
0.495 in 12.6 mm |
2 TC | 19/0.0117 TC | Coax Cable |
507-64A | 64A* |
50.0 pF/ft 164 pF/m |
Rubber-IV | 48 Ω |
Rubber-IV Rubber-IV |
0.475 in 12.1 mm |
2 TC | 19/0.0117 TC | Coax Cable |
507-65 | 65 |
44.0 pF/ft 144 pF/m |
PE | 950 Ω |
PVC-I PVC-I |
0.405 in 10.3 mm |
BC | 0.0080 Formex F | Coax Cable |
507-65A | 65A* |
44.0 pF/ft 144 pF/m |
PE | 950 Ω |
PVC-IIA PVC-IIA |
0.405 in 10.3 mm |
BC | 0.0080 Formex F | Coax Cable |
507-66 | 66 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-67 | 67 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-68 | 68 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-69 | 69 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-6A | 6A* |
22.0 pF/ft 72.2 pF/m |
PE | 75 Ω |
PVC-IIA PVC-IIA |
0.332 in 8.43 mm |
BC-S | 0.0285 CW | Coax Cable |
507-7 | 7 |
12.5 pF/ft 41.0 pF/m |
Air space PE | 95 Ω |
PVC-I PVC-I |
0.370 in 9.40 mm |
BC | 0.0359 BC | Coax Cable |
507-70 | 70 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Not assigned |
507-71 | 71 |
13.5 pF/ft 44.3 pF/m |
Air space PE | 93 Ω |
PVC-I PVC-I |
0.245 in 6.22 mm |
2 TC | 0.0253 CW | Coax Cable |
507-71A | 71A |
13.5 pF/ft 44.3 pF/m |
Air space PE | 93 Ω |
PE-III PE-III |
0.245 in 6.22 mm |
2 TC | 6.22 mm | Coax Cable |
507-71B | 71B* |
14.5 max. pF/ft 47.6 max. pF/m |
Air space PE | 93 Ω |
PE-IIIA PE-IIIA |
0.250 max. in 6.35 max. mm |
2 TC | 0.0253 CW | Coax Cable |
507-72 | 72 |
7.8 pF/ft 26 pF/m |
Air space PE | 150 Ω |
PVC-I PVC-I |
0.630 in 16.0 mm |
BC | 0.0253 CW | Coax Cable |
507-73 | 73 |
61.8 pF/ft 203 pF/m |
PE | 25 Ω |
None None |
0.175 in 4.45 mm |
2 BC | 0.0320 BC | Coax Cable |
507-74 | 74 |
29.6 pF/ft 97.1 pF/m |
PE | 52 Ω |
PVC-II w/armor PVC-II w/armor |
0.603 in 15.3 mm |
2 BC | 0.1020 BC | Coax Cable |
507-74A | 74A* |
29.6 pF/ft 97.1 pF/m |
PE | 52 Ω |
PVC-IIA w/armor PVC-IIA w/armor |
0.603 in 15.3 mm |
2 BC | 0.1020 BC | Coax Cable |
507-75 | 75 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-76 | 76 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Stub supported coaxial |
507-77A | 77A |
50.0 pF/ft 164 pF/m |
Rubber | 48 Ω |
PVC-IIA PVC-IIA |
0.450 in 11.4 mm |
2 TC | 19/0.0117 TC | Coax Cable |
507-78A | 78A |
50.0 pF/ft 164 pF/m |
Rubber | 48 Ω |
PVC-IIA PVC-IIA |
0.420 in 10.7 mm |
TC | 19/0.0117 TC | Coax Cable |
507-79 | 79 |
11.0 pF/ft 36.1 pF/m |
Air space PE | 125 Ω |
PVC-I w/armor PVC-I w/armor |
0.475 in 12.1 mm |
BC | 0.0253 CW | Coax Cable |
507-79A | 79A |
11.0 max. pF/ft 36.1 max. pF/m |
Air space PE | 125 Ω |
PVC-I w/armor PVC-I w/armor |
0.475 in 12.1 mm |
BC | 0.0253 CW | Coax Cable |
507-79B | 79B* |
11.0 max. pF/ft 36.1 max. pF/m |
Air space PE | 125 Ω |
PVC-IIA w/armor PVC-IIA w/armor |
0.475 in 12.1 mm |
BC | 0.0253 CW | Coax Cable |
507-8 | 8 |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-I PVC-I |
0.405 in 10.3 mm |
BC | 7/21 BC | Coax Cable |
507-80 | 80 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Bead supported coaxial |
507-81 | 81* |
37.0 pF/ft 121 pF/m |
Mag. Ox. | 50 Ω |
None None |
0.325 in 8.26 mm |
BC Tube | 0.0625 BC | Coax Cable |
507-82 | 82* |
36.0 pF/ft 118 pF/m |
Mag. Ox. | 50 Ω |
None None |
0.750 in 19.1 mm |
BC Tube | 0.1250 BC | Coax Cable |
507-83 | 83 |
44.0 pF/ft 144 pF/m |
PE | 35 Ω |
PVC-I PVC-I |
0.405 in 0.405 in |
BC | 0.1020 BC | Coax Cable |
507-84A | 84A* |
21.5 pF/ft 70.5 pF/m |
PE | 75 Ω |
PVC-IIA w/lead PVC-IIA w/lead |
1.000 in 25.40 mm |
BC | 25.40 mm | Coax Cable |
507-85A | 85A* |
21.5 pF/ft 70.5 pF/m |
PE | 75 Ω |
PVC-IIA w/lead PVC-IIA w/lead |
1.565 in 39.75 mm |
BC | 0.1045 BC | Coax Cable |
507-86 | 86* |
7.8 pF/ft 26 pF/m |
PE | 200 Ω |
None None |
0.650 x 0.300 in 16.5 x 7.62 mm |
None | 2 cond. 7/21 BC | Coax Cable |
507-87 | 87 |
29.5 pF/ft 96.8 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.425 in 10.8 mm |
BC & S | 7/20 S | Coax Cable |
507-87A | 87A* |
29.5 pF/ft 96.8 pF/m |
TFE | 50 Ω |
FG-V FG-V |
0.425 in 10.8 mm |
2 S | 7/20 S | Coax Cable |
507-88 | 88* |
50.0 pF/ft 164 pF/m |
164 pF/m | 48 Ω |
PVC-I PVC-I |
0.515 max. in 13.1 max. mm |
4 TC | 19/0.0117 TC | Coax Cable |
507-88A | 88A* |
50.0 pF/ft 164 pF/m |
Rubber | 48 Ω |
PVC-IIA PVC-IIA |
0.515 max. in 13.1 max. mm |
4 TC | 19/0.0117 TC | Coax Cable |
507-88B | 88B |
50.0 pF/ft 164 pF/m |
Rubber | 48 Ω |
Rubber-IV Rubber-IV |
0.565 in 14.4 mm |
4 TC | 19/0.0117 TC | Coax Cable |
507-89 | 89 |
10.0 pF/ft 32.8 pF/m |
Air space PE | 125 Ω |
PVC-I PVC-I |
0.632 in 16.1 mm |
BC | 0.0253 CW | Coax Cable |
507-8A | 8A* |
29.5 pF/ft 96.8 pF/m |
PE | 52 Ω |
PVC-IIA PVC-IIA |
0.405 in 10.3 mm |
BC | 7/21 BC | Coax Cable |
507-9 | 9 |
30.0 pF/ft 98.4 pF/m |
PE | 50 Ω |
PVC-II PVC-II |
0.420 in 10.7 mm |
BC-S | 7/21 S | Coax Cable |
507-90 | 90 |
30.8 pF/ft 101 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.425 in 10.8 mm |
2 TC 1 GS |
7/24 S | Coax Cable |
507-91 | 91 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-92 | 92 |
N/A N/A |
SS TFE | 46 Ω |
None None |
N/A N/A |
BC Tube | 0.375 BC | Coax Cable |
507-93 | 93 |
29.0 pF/ft 95.1 pF/m |
TFE tape | 50 Ω |
FG-V FG-V |
0.710 in 18.0 mm |
BC | 19/18 BC | Coax Cable |
507-94 | 94* |
29.0 pF/ft 95.1 pF/m |
TFE tape | 50 Ω |
FG-V FG-V |
0.445 in 11.3 mm |
2 BC | 19/23 S | Coax Cable |
507-94A | 94A |
29.0 pF/ft 95.1 pF/m |
TFE tape | 50 Ω |
FG-V FG-V |
0.500 in 12.7 mm |
2 BC | 19/22 S | Coax Cable |
507-95 | 95 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-96 | 96 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-97 | 97 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-98 | 98 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-99 | 99 |
N/A N/A |
N/A | N/A |
N/A N/A |
N/A N/A |
N/A | N/A | Waveguide |
507-9A | 9A |
30.0 pF/ft 98.4 pF/m |
PE | 50 Ω |
PVC-II PVC-II |
0.420 in 10.7 mm |
2 S | 7/21 S | Coax Cable |
507-9B | 9B* |
30.0 pF/ft 98.4 pF/m |
PE | 50 Ω |
PVC-IIA PVC-IIA |
0.420 in 10.7 mm |
2 S | 7/21 S | Coax Cable |
N/A | 1 |
N/A |
N/A | N/A |
N/A N/A |
N/A |
N/A | N/A | Waveguide |
N/A | 2 |
N/A |
N/A | N/A |
N/A N/A |
N/A |
N/A | N/A | Waveguide |
N/A | 3 |
N/A |
N/A | N/A |
N/A N/A |
0.226 in 5.74 mm |
N/A | N/A | Waveguide |