1099-76C
USES: General appliance wiring and other applications where chemical exposure, temperature extremes, and dielectric stress are possible.
Downloads
Specifications
AWG Size
20
Conductor
Silver plated copper
Conductor Diameter
0.032 in
0.813 mm
0.813 mm
Insulation
Extruded PTFE wall thickness for 8 AWG is 0.030" (0.76 mm); wall thickness for 10-30 AWG is 0.020" (0.51 mm)
Insulation Diameter
0.077 in
1.96 mm
1.96 mm
Max Resistance @ 20°C (@ 68°F)
10.1 Ohms/1000 ft
33.1 Ohms/km
33.1 Ohms/km
Stranding
Solid
Temperature
200° C for UL and CSA
Voltage
600 V (UL allows 2,500V peak for electronic use only)
Weight
7.00 lbs/1000 ft
10.4 kgs/km
10.4 kgs/km
Identification
Surface printed as required by UL or CSA