1104-10
CONDUCTOR: 27% nickel-coated copper.
INSULATION: Inorganic dielectric, PTFE/ polyimide composite fluid/mechanical barrier.
JACKET: PTFE glass braid or fused PTFE tape wrapped.
VOLTAGE: 600V
TEMPERATURE: 260°
USES: Fire resistant high temperature wire where resistance to moisture, abrasion, oils, and fluids is required. High insulation resistance for short intervals (15 minutes) when exposed to open flame of 1093°C (2000°F).
NOTE:- MIL-DTL-27500 Basic Wire Specification : JA
Downloads
Specifications
AWG Size
18
Conductor
27% nickel-coated copper.
Max. Diameter
0.135 in
3.43 mm
3.43 mm
Min. Diameter
0.119 in
3.02 mm
3.02 mm
Insulation
Inorganic dielectric, PTFE/ polyimide composite fluid/mechanical barrier.
Jacket
PTFE glass braid or fused PTFE tape wrapped.
Max Resistance @ 20°C (@ 68°F)
9.14 Ohms/1000 ft
30.0 Ohms/km
30.0 Ohms/km
Stranding
19/30
Temperature
260 ºC
Voltage
600 V
Weight
15 lbs/1000 ft
22 kgs/km
22 kgs/km