5119-S
CONDUCTORS: Stranded tinned copper.
INSULATION: 0.010″ Semi-rigid, -55° C to 105° C PVC Type “B” to MIL-DTL-16878/1.
VOLTAGE: 600 V.
CODED: Numbered consecutively in black on white.
CABLED: Round with fillers where needed.
SHIELD: Braided tinned copper, 80% coverage.
JACKET: Black flexible PVC, -40° C to 105° C.
USES: Interconnecting cables for electronic equipment, telemetering, and instrumentation control. Resistant to flame, moisture, and many oils and chemicals.
Specifications
AWG Size
22
Cabled
Round with fillers where needed.
Cable O.D.
0.481 in
12.2 mm
12.2 mm
Coded
Numbered consecutively in black on white.
Conductor
Stranded tinned copper
Insulation
0.010" Semi-rigid, -55° C to 105° C PVC Type "B" to MIL-DTL-16878/1.
Jacket
Black flexible PVC, -40° C to 105° C.
Jacket Thickness
0.040 in
1.02 mm
1.02 mm
No. of Cond.
40
Shield
Braided tinned copper, 80% coverage.
Stranding
7/30
Voltage
600 V
Weight
183 lbs/1000 ft
272 kgs/km
272 kgs/km
Capacitance (Between Adjacent Conductors)
35 pF/ft